Seeing a fault code on your Amana air conditioner? This guide explains what the most common Amana air conditioner error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed HVAC technicians for Amana air conditioner repair across Metro Vancouver and the Fraser Valley.
The codes below apply across common Amana models (ComfortNet, standard). Meanings follow Amana’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.
How to read Amana air conditioner error codes
Amana central ACs share the Goodman/Daikin platform. Basic single-stage Amana ACs (e.g. ASXC/ASX/ANX 'standard' split units) have NO on-unit fault-code display – the outdoor contactor simply energizes or not, and most AC-related faults are reported by the matched indoor air-handler or gas-furnace control board (2-character 7-segment diagnostic characters) rather than by the condenser. The premium communicating variable-speed inverter line (ComfortNet-compatible, e.g. AVXC20) shows numbered E-codes on the outdoor control-board 7-segment LED AND scrolls a plain-language ClimateTalk fault message on the ComfortNet / CTK0x communicating thermostat. Outdoor inverter faults use E-codes (E11-E55) plus Ed0-Ed3 data/configuration codes; communicating air-handler faults use 2-character codes (Ed, E5, EF, b0/b9, d0/d1, C1/C2, etc.). The board stores the six most recent system faults (7-segment Screen One / FAULT RECALL), and the ComfortNet thermostat lists recent faults under Equipment Status / Diagnostics. Codes here are from official Amana AVXC20 outdoor and AVPTC**14 air-handler service/installation manuals; meanings can vary by model and major revision.
Amana air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Amana air conditioners across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairAmana air conditioner error codes & what they mean
These are the Amana air conditioner codes our Greater Vancouver technicians see most. Anything marked pro repair involves electrical, refrigerant, sensor or control-board work that must be done by a licensed HVAC technician — never open the indoor/outdoor unit or refrigerant lines yourself.
| Code | What it usually means | Common causes | Safe to check yourself |
|---|---|---|---|
| E11 / RUN SYS TEST | Thermostat/board message that the required start-up System Verification Test must be run after install or a data/board change (commissioning step, not a hardware failure) pro repair | Initial system test not yet completed after installation; Control board replaced or shared data changed | No action needed by the homeowner; the installer runs the System Verification Test from the ComfortNet menu |
| E13 / HI PRESSURE M | High pressure (minor) – the unit is experiencing high-pressure faults pro repair | Blocked or dirty condenser coil; Service (stop) valve not fully open; Refrigerant overcharge | Clear leaves, grass and debris from around the outdoor condenser and keep airflow paths open; Set the thermostat to Cool and try one single power cycle at the breaker |
| E15 / LOW PRESSURE C | Low pressure (critical) – the unit is experiencing low-pressure faults pro repair | Service (stop) valve not fully open; Restriction in the refrigerant lines; Low refrigerant charge / refrigerant leak | Replace a dirty air filter and make sure indoor supply/return airflow is not blocked; Set the thermostat to Cool and retry once |
| E17 / COMPRESSOR FAIL | Compressor failure – the unit is experiencing frequent compressor faults pro repair | Service (stop) valve not fully open; Compressor wiring fault / lost phase; Compressor motor failure | Try one single power cycle at the breaker |
| E19 / PCB OR FAN FAIL | Outdoor control board and/or outdoor fan motor fault pro repair | Obstruction in fan rotation; Outdoor fan motor not connected properly; Outdoor fan not running | Check the outdoor fan grille for debris (leaves/branches) and clear obstructions; Try one single power cycle at the breaker |
| E21 / EEV CTRL FAIL | Electronic expansion valve (EEV) control fault pro repair | EEV not connected properly; Faulty EEV or control board | No homeowner fix; requires technician service |
| E22 / HI DISCH TEMP | High discharge temperature – frequent high discharge-temperature faults pro repair | Discharge thermistor inoperable or improperly positioned/connected; Low refrigerant charge or overcharge; Faulty compressor | Make sure the outdoor condenser is clear of debris; Try one single power cycle at the breaker |
| E23 / DISCH TEMP FAIL | Discharge temperature sensor out of range / sensor failure pro repair | Discharge thermistor inoperable or improperly connected | No homeowner fix; requires technician sensor service |
| E24 / HPS OPEN | The high-pressure switch is open pro repair | High-pressure switch inoperable; Underlying high-pressure condition (dirty coil, blocked condenser, overcharge, outdoor fan not running) | Clear debris from around the outdoor condenser; Set the thermostat to Cool and try one single power cycle at the breaker |
| E26 / PRESSURE SENSOR | Pressure sensor not reacting properly / pressure sensor malfunction pro repair | Pressure sensor inoperable or not properly connected | No homeowner fix; requires technician service |
| E28 / COIL TEMP FAIL2 | Outdoor coil temperature sensor out of range / sensor failure pro repair | Outdoor coil thermistor inoperable or improperly connected | No homeowner fix; requires technician sensor service |
| E29 / LIQ TEMP FAIL | Liquid line temperature sensor out of range / sensor failure pro repair | Liquid-line thermistor inoperable or improperly connected | No homeowner fix; requires technician sensor service |
| E31 / HI LEAK CURRENT | High leakage current detected (high-voltage leakage to ground) pro repair | Improper ground; Faulty compressor | Turn the unit off and leave it off; this is an electrical fault – call a licensed technician |
| E32 / HI TEMP CTRL1 | High temperature fault on the outdoor control board pro repair | Outdoor control board overheating; Restricted airflow around the outdoor unit electronics; Faulty control board | Make sure the outdoor unit is clear of debris and has open airflow; Try one single power cycle at the breaker |
| E34 / CURRENT SPIKE | High current condition detected, indicating potential for a short circuit pro repair | Current spike in supply; Service (stop) valve not fully open; Compressor wiring fault / lost phase | Leave the unit off; this is an electrical fault – call a licensed technician |
| E35 / HIGH CURRENT | High current condition detected on the outdoor control board pro repair | Short-circuit condition; Service (stop) valve not fully open; Refrigerant overcharge | Leave the unit off; this is an electrical fault – call a licensed technician |
| E36 / STARTUP ERROR | Abnormal condition detected during the compressor startup procedure pro repair | Service (stop) valve not fully open; Compressor or wiring problem; Faulty control board | Try one single power cycle at the breaker |
| E38 / COMP VOLTAGE | Voltage-related issue with the compressor detected pro repair | Compressor wiring fault; Supply voltage problem; Faulty control board or compressor | Check the breaker for the AC is fully ON (not tripped); Try one single power cycle at the breaker |
| E40 / COMP MISMATCH | Compressor requirement differs from the installed compressor capability (mismatch) pro repair | Incorrect shared data / configuration; Wrong board or compressor for the unit | No homeowner fix; requires technician data/configuration service |
| E41 / LOW REFRIGERANT | Control detected a low refrigerant condition pro repair | Refrigerant leak; Low refrigerant charge; Thermistors inoperable or not properly connected | No homeowner fix; refrigerant work must be done by a licensed technician |
| E42 / LOW LINE VOLT | Control detected a low power-supply voltage condition pro repair | Low line voltage supply; Tripped breaker / blown fuse; Utility supply issue | Check the breaker for the AC is fully ON (not tripped); Try one single power cycle at the breaker |
| E43 / HIGH LINE VOLT | Control detected a high power-supply voltage condition pro repair | High line voltage supply; Utility supply issue | No homeowner fix; line-voltage issue requires a technician/utility |
| E44 / OP TEMP RANGE | Outdoor temperature is outside the recommended operating range; the unit may still operate normally DIY-checkable | Ambient air temperature too high or too low for normal operation | Wait and retry during a more moderate outdoor temperature; Try one single power cycle at the breaker |
| E45 / NO COOLING TEST | Unable to start the cooling-mode test because indoor heat is on (commissioning message, not a failure) pro repair | Indoor heat active during a technician test | No homeowner action; the technician turns off indoor heat to run the test |
| E47 / NO SYS VER TEST | Unable to start the system verification test because indoor heat is on (commissioning message, not a failure) pro repair | Indoor heat active during the system verification test | No homeowner action; the technician turns off indoor heat to run the test |
| E48 / NO PUMP DOWN | Control unable to enter Pump Down Mode because indoor heat is on (service message, not a failure) pro repair | Indoor heat active during a technician pump-down procedure | No homeowner action; technician procedure only |
| E49 / NO CHARGE MODE | Control unable to enter Charging Mode because indoor heat is on (service message, not a failure) pro repair | Indoor heat active during a technician charging procedure | No homeowner action; technician procedure only |
| E50 / LINE VOLT CTRL | Voltage issue detected on the outdoor control board pro repair | High or low voltage from supply; Faulty control board | Check the breaker is fully ON; Try one single power cycle at the breaker |
| E51 / OD COMM ERROR | Communication issue detected by the outdoor control board (communicating/ComfortNet system) pro repair | Communication wiring disconnected or loose; Wiring damage between indoor and outdoor units | Try one single power cycle at the breaker |
| E52 / COMP FAIL MINOR | Frequent compressor faults detected (minor) pro repair | Service (stop) valve not fully open; Compressor wiring issue; Compressor problem | Try one single power cycle at the breaker |
| E54 / HI DIS TEMP MIN | Frequent high discharge-temperature faults (minor) pro repair | Discharge thermistor problem; Low refrigerant charge or overcharge; Restricted condenser airflow | Make sure the outdoor condenser is clear of debris; Try one single power cycle at the breaker |
| Ed0 / NO ID AIRFLOW | Outdoor control sees estimated indoor airflow near 0 CFM (indoor blower not delivering airflow) pro repair | Indoor blower not running; Severely restricted filter/ductwork; Communication or wiring issue with the indoor unit | Replace a dirty air filter and open all supply/return vents; Try one single power cycle at the breaker |
| Ed1 / INVALID DATA | Outdoor control board lacks the appropriate shared data needed to operate pro repair | Missing or invalid shared data on the network; Communicating system not commissioned | No homeowner fix; requires technician data programming |
| Ed2 / INVALID SYSTEM | Airflow requirement exceeds the indoor subsystem capability (system mismatch) pro repair | Indoor and outdoor unit not matched for required airflow; Incorrect shared data | No homeowner fix; requires technician configuration |
| Ed3 / INVALID CONFIG / INVALID MC DATA | Mismatch between shared data and hardware, or rejected memory-card/data-loader data pro repair | Shared data incompatible with the installed hardware; Data-loader/memory-card data rejected or wrong | No homeowner fix; requires technician data programming |
| Ed (air handler) / FUSE OPEN | Control fuse open on the communicating air-handler board (24V control fuse blown) pro repair | Blown control-board fuse; Short in the 24V control wiring; Loose or open low-voltage connection | Confirm the outdoor disconnect and indoor breaker are ON; Set the thermostat to Cool with a low setpoint; Try one single power cycle at the breaker |
| EF (air handler) / BLOWER MOTOR COMMUNICATION ERROR | Communication error between the air-handler control board and the blower motor pro repair | Loose or incorrect blower motor wiring; Power interruption / low voltage; Faulty control board or blower motor | Try one single power cycle at the breaker |
| P2 (air handler) / BLOWER MOTOR NOT RUNNING | Indoor blower motor is not running pro repair | Fan/motor obstruction; Power interruption / low voltage; Loose or incorrect wiring | Check and replace a dirty air filter; Make sure supply and return vents are open and unblocked; Try one single power cycle at the breaker |
| dF (air handler) / LOW INDOOR AIRFLOW | Estimated indoor airflow is lower than the airflow requirement (low indoor airflow) pro repair | Excessive duct static pressure (restricted ductwork/filter); Failed indoor blower motor; Blower motor not properly connected | Replace a dirty air filter; Open all supply and return vents and clear any blockage; Make sure the return grille is not obstructed |
| C1 (air handler) / DATA NOT ON NETWORK | The air-handler control board does not have the shared data it needs on the network to operate pro repair | No shared data loaded on the network; Communicating system not yet commissioned | No homeowner fix; requires technician data programming |
| C2 (air handler) / INVALID DATA ON NETWORK | Invalid shared data on the network for the air-handler control pro repair | Wrong or invalid shared data on the network | No homeowner fix; requires technician data programming |
Amana air conditioner codes we get called for most
E19 / PCB OR FAN FAIL — Outdoor control board and/or outdoor fan motor fault
Typical causes include obstruction in fan rotation; outdoor fan motor not connected properly; outdoor fan not running. A few things are safe to check yourself (Check the outdoor fan grille for debris (leaves/branches) and clear obstructions; Try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E19 / PCB OR FAN FAIL on Amana air conditioners throughout Greater Vancouver.
E23 / DISCH TEMP FAIL — Discharge temperature sensor out of range / sensor failure
Typical causes include discharge thermistor inoperable or improperly connected. A few things are safe to check yourself (No homeowner fix; requires technician sensor service), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E23 / DISCH TEMP FAIL on Amana air conditioners throughout Greater Vancouver.
E17 / COMPRESSOR FAIL — Compressor failure – the unit is experiencing frequent compressor faults
Typical causes include service (stop) valve not fully open; compressor wiring fault / lost phase; compressor motor failure. A few things are safe to check yourself (Try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E17 / COMPRESSOR FAIL on Amana air conditioners throughout Greater Vancouver.
E13 / HI PRESSURE M — High pressure (minor) – the unit is experiencing high-pressure faults
Typical causes include blocked or dirty condenser coil; service (stop) valve not fully open; refrigerant overcharge. A few things are safe to check yourself (Clear leaves, grass and debris from around the outdoor condenser and keep airflow paths open; Set the thermostat to Cool and try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E13 / HI PRESSURE M on Amana air conditioners throughout Greater Vancouver.
Is it safe to keep running a Amana air conditioner with a fault code?
Most Amana fault codes put the air conditioner into a safe lockout for a reason. You can safely check the basics — the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool — and restart it once. If the code returns, stop and book a technician. Air-conditioner faults are electrical and refrigerant issues — never open the unit or touch the wiring or refrigerant lines yourself.
Amana air conditioner repair across Greater Vancouver
HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Amana air conditioners — sensor and thermistor errors, communication faults, fan and compressor problems, refrigerant and pressure faults, and control-board issues — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your air conditioner is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.
Need it sorted fast? We offer priority emergency air conditioner repair. Explore Air Conditioner services, browse all air conditioner error codes by brand, or request a free estimate.
Amana air conditioner service areas
We repair Amana air conditioners across Greater Vancouver and the Fraser Valley, including:
Amana air conditioner error code FAQs
Can I reset my Amana air conditioner myself?
Yes — power-cycling the unit at the breaker once is generally safe after you’ve checked the basics (the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool). If the air conditioner faults again right away, stop and note the code — repeatedly resetting a air conditioner that keeps locking out can mask a real problem. Call a licensed HVAC technician to diagnose it.
What does the Amana E17 / COMPRESSOR FAIL code mean?
On Amana air conditioners, E17 / COMPRESSOR FAIL commonly indicates compressor failure – the unit is experiencing frequent compressor faults. Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed HVAC technician. HeatLand fixes this across Greater Vancouver.
Do you repair Amana air conditioners you didn’t install?
Yes. HeatLand is brand-agnostic and services Amana air conditioners throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.
Is a Amana air conditioner fault code an emergency?
No heat in cold weather or no cooling in a heat wave is worth treating urgently. For priority air conditioner repair across Greater Vancouver, call (604) 330-3812.
How much does Amana air conditioner repair cost in Vancouver?
It depends on the fault. Many Amana codes point to sensors, thermistors, capacitors or control parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.
Amana air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Amana air conditioners across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairMore Air Conditioner error-code guides
HeatLand repairs every major air conditioner brand across Greater Vancouver. More brand guides:
Daikin air conditioner codes
35 Daikin air conditioner fault codes — meanings, causes & repair.
Goodman air conditioner codes
28 Goodman air conditioner fault codes — meanings, causes & repair.
Rheem air conditioner codes
45 Rheem air conditioner fault codes — meanings, causes & repair.
Lennox air conditioner codes
33 Lennox air conditioner fault codes — meanings, causes & repair.
Carrier air conditioner codes
29 Carrier air conditioner fault codes — meanings, causes & repair.
Bryant air conditioner codes
26 Bryant air conditioner fault codes — meanings, causes & repair.