Bryant Air Conditioner Error Codes — Meanings, Causes & Repair in Greater Vancouver

Bryant Air Conditioner Error Codes — Meanings, Causes & Repair in Greater Vancouver

Seeing a fault code on your Bryant air conditioner? This guide explains what the most common Bryant air conditioner error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed HVAC technicians for Bryant air conditioner repair across Metro Vancouver and the Fraser Valley.

The codes below apply across common Bryant models (Evolution, Preferred, Legacy). Meanings follow Bryant’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.

How to read Bryant air conditioner error codes

Bryant uses the same communicating platform as Carrier (Bryant Evolution = Carrier Infinity). On Evolution two-stage and variable-speed air conditioners, faults appear as 2- or 3-digit numbers on the Evolution Connex (Touch) wall control under the system status/fault history menu. The same numeric codes are shown on the outdoor unit control board by the amber STATUS LED: short flashes give the first digit and long flashes give the second digit. A separate green COMM LED indicates successful communication with the rest of the system (off until communication is established, on continuously once a valid command is received, and it turns off after about 2 minutes with no communication). Basic single-stage Preferred and Legacy air conditioners paired with a standard (non-communicating) thermostat have no on-board numeric code display.

Bryant air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Bryant air conditioners across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

Bryant air conditioner error codes & what they mean

These are the Bryant air conditioner codes our Greater Vancouver technicians see most. Anything marked pro repair involves electrical, refrigerant, sensor or control-board work that must be done by a licensed HVAC technician — never open the indoor/outdoor unit or refrigerant lines yourself.

CodeWhat it usually meansCommon causesSafe to check yourself
16System communications failure. The outdoor control has lost communication with the Evolution wall control or indoor unit pro repairLoss of communication signal on the low-voltage data wires; Loose, corroded, or miswired low-voltage connections; Damaged or pinched thermostat/communication cableConfirm the outdoor disconnect and the breaker are switched on; Set the thermostat to Cool and lower the setpoint to confirm a cooling call; Try a single power-cycle at the breaker, wait a few minutes, then restart
25Invalid model plug. The model-identification plug on the outdoor control board is missing, wrong, or unreadable, so the control cannot configure the unit pro repairMissing or incorrect model plug after a board replacement; Damaged model plug; Failed control boardConfirm the disconnect and breaker are on; Try a single power-cycle at the breaker, wait a few minutes, then restart
31High pressure switch open. The refrigerant high-pressure switch has tripped, indicating excessive system pressure pro repairDirty or blocked outdoor condenser coil; Restricted airflow over the outdoor coil; Outdoor fan not runningClear leaves, grass, and debris away from the outdoor condenser unit and make sure airflow around it is unobstructed; Replace or clean a dirty indoor air filter; Confirm the disconnect and breaker are on
32Low pressure switch open. The refrigerant low-pressure switch has tripped, indicating low system pressure pro repairLow refrigerant charge / refrigerant leak; Restricted indoor airflow (dirty filter, blocked coil); Failed low-pressure switchReplace or clean a dirty indoor air filter; Make sure supply and return vents are open and unblocked; Confirm the thermostat is set to Cool
45Control fault. An internal fault was detected in the outdoor unit control board pro repairFailed or faulty outdoor control board; Power-supply / voltage irregularity affecting the controlConfirm the disconnect and breaker are on; Try a single power-cycle at the breaker, wait a few minutes, then restart
46Brown out (230V). Incoming line voltage dropped below the acceptable threshold for a sustained period pro repairUtility low-voltage / brownout condition; Undersized or loose line-voltage wiring; Overloaded electrical circuitCheck whether other appliances/lights are also dimming or losing power (possible utility issue); Confirm the disconnect and breaker are on; Try a single restart once normal power is confirmed
47No 230V at unit. Line voltage (230V) is not present at the outdoor unit / contactor pro repairOutdoor disconnect pulled or off; Tripped breaker; Blown fuse at the disconnectConfirm the outdoor disconnect switch is fully engaged (on); Reset the breaker once if it is tripped; Try a single restart after power is restored
53Outdoor air temperature sensor fault. The outdoor air temperature sensor reading is out of range or has failed pro repairFailed or disconnected outdoor air temperature thermistor; Loose or corroded sensor connection; Damaged sensor wiringConfirm the disconnect and breaker are on; Try a single restart
55Outdoor coil sensor fault. The outdoor coil temperature sensor reading is out of range or has failed pro repairFailed or disconnected outdoor coil thermistor; Loose or corroded sensor connection; Damaged sensor wiringConfirm the disconnect and breaker are on; Try a single restart
56Thermistors out of range. The outdoor temperature sensors show an improper or inconsistent reading relationship pro repairOne or more outdoor thermistors out of calibration or failed; Sensor mounting or wiring problemConfirm the disconnect and breaker are on; Try a single restart
71Low stage thermal cutout. The compressor internal overload (thermal protector) tripped while running in low stage pro repairCompressor overheating; Dirty outdoor condenser coil / restricted airflow; Outdoor fan problemClear debris from around the outdoor condenser and ensure airflow is unobstructed; Replace or clean a dirty indoor air filter; Allow the unit to cool, then try a single restart
72High stage thermal cutout. The compressor internal overload (thermal protector) tripped while running in high stage pro repairCompressor overheating; Dirty outdoor condenser coil / restricted airflow; Outdoor fan problemClear debris from around the outdoor condenser and ensure airflow is unobstructed; Replace or clean a dirty indoor air filter; Allow the unit to cool, then try a single restart
73Contactor shorted. Compressor voltage was sensed when the contactor should be open (contactor stuck closed / welded) pro repairWelded or stuck-closed contactor; Failed contactor; Control board faultConfirm the disconnect and breaker are on; Do not open the unit; call a technician
74No 230V at compressor. Line voltage is not being sensed at the compressor (applies to applicable two-capacity outdoor units) pro repairFailed contactor not closing; Open compressor circuit or wiring; Blown internal fuseConfirm the disconnect and breaker are on; Try a single restart after confirming power
75Low stage did not start. The compressor failed to start in low stage when commanded pro repairFailed start components; Seized or faulty compressor; Open winding or wiringConfirm the disconnect and breaker are on; Try a single restart
76Low stage did not start 3 times. Low stage failed to start repeatedly and the stage is locked out pro repairPersistent start failure; Faulty compressor or start components; Electrical supply problemConfirm the disconnect and breaker are on; Wait for the lockout to clear, then try a single restart
77High stage did not start. The compressor failed to start in high stage when commanded pro repairFailed start components; Faulty compressor; Open winding or wiringConfirm the disconnect and breaker are on; Try a single restart
78High stage did not start 3 times. High stage failed to start repeatedly and the stage is locked out pro repairPersistent start failure; Faulty compressor or start components; Electrical supply problemConfirm the disconnect and breaker are on; Wait for the lockout to clear, then try a single restart
81Low stage thermal lockout. After repeated low-stage thermal cutouts, low stage is locked out (about 4 hours, or until 24V power is recycled) pro repairRepeated compressor overheating; Dirty condenser coil / airflow restriction; Charge or electrical faultClear debris from around the outdoor condenser; Replace or clean a dirty indoor air filter; Allow the lockout to expire; if it returns, call a technician
82High stage thermal lockout. After repeated high-stage thermal cutouts, high stage is locked out (about 4 hours, or until 24V power is recycled) pro repairRepeated compressor overheating; Dirty condenser coil / airflow restriction; Charge or electrical faultClear debris from around the outdoor condenser; Replace or clean a dirty indoor air filter; Allow the lockout to expire; if it returns, call a technician
83Low-pressure lockout. After repeated low-pressure switch trips, the unit is locked out (about 4 hours, or until 24V power is recycled) pro repairLow refrigerant charge / leak; Restricted indoor airflow; Repeated low-pressure tripsReplace or clean a dirty indoor air filter; Make sure vents are open and unblocked; Allow the lockout to expire; if it returns, call a technician
84High-pressure lockout. After repeated high-pressure switch trips, the unit is locked out (about 4 hours, or until 24V power is recycled) pro repairDirty/blocked outdoor condenser coil; Restricted condenser airflow or failed outdoor fan; Overcharge or non-condensablesClear leaves, grass, and debris away from the outdoor condenser and ensure airflow is unobstructed; Replace or clean a dirty indoor air filter; Allow the lockout to expire; if it returns, call a technician
85Low contactor open. The low-stage contactor circuit is sensed open when it should be closed (applies to applicable two-capacity outdoor units) pro repairFailed or stuck-open contactor; Open control wiring; Control board faultConfirm the disconnect and breaker are on; Do not open the unit; call a technician
87High contactor open. The high-stage contactor circuit is sensed open when it should be closed (applies to applicable two-capacity outdoor units) pro repairFailed or stuck-open contactor; Open control wiring; Control board faultConfirm the disconnect and breaker are on; Do not open the unit; call a technician
178Indoor unit communication fault. The Evolution Connex wall control has lost communication with the indoor furnace or fan coil. Communicating Evolution systems only pro repairLoose or corroded communication wiring between wall control and indoor unit; Blown indoor low-voltage fuse; Failed indoor control boardConfirm the indoor unit (furnace/air handler) breaker and switch are on; Confirm the wall control screen is powered; Try a single power-cycle at the breaker, wait a few minutes, then restart
179Outdoor unit communication fault. The Evolution Connex wall control has lost communication with the outdoor unit (air conditioner or heat pump). Communicating Evolution systems only pro repairLoose, corroded, or miswired communication wiring to the outdoor unit; Loss of power to the outdoor unit; Failed outdoor control boardConfirm the outdoor disconnect and breaker are on; Set the thermostat to Cool to confirm a cooling call; Try a single power-cycle at the breaker, wait a few minutes, then restart

Bryant air conditioner codes we get called for most

16 — System communications failure. The outdoor control has lost communication with the Evolution wall control or indoor unit

Typical causes include loss of communication signal on the low-voltage data wires; loose, corroded, or miswired low-voltage connections; damaged or pinched thermostat/communication cable. A few things are safe to check yourself (Confirm the outdoor disconnect and the breaker are switched on; Set the thermostat to Cool and lower the setpoint to confirm a cooling call), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes 16 on Bryant air conditioners throughout Greater Vancouver.

53 — Outdoor air temperature sensor fault. The outdoor air temperature sensor reading is out of range or has failed

Typical causes include failed or disconnected outdoor air temperature thermistor; loose or corroded sensor connection; damaged sensor wiring. A few things are safe to check yourself (Confirm the disconnect and breaker are on; Try a single restart), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes 53 on Bryant air conditioners throughout Greater Vancouver.

71 — Low stage thermal cutout. The compressor internal overload (thermal protector) tripped while running in low stage

Typical causes include compressor overheating; dirty outdoor condenser coil / restricted airflow; outdoor fan problem. A few things are safe to check yourself (Clear debris from around the outdoor condenser and ensure airflow is unobstructed; Replace or clean a dirty indoor air filter), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes 71 on Bryant air conditioners throughout Greater Vancouver.

31 — High pressure switch open. The refrigerant high-pressure switch has tripped, indicating excessive system pressure

Typical causes include dirty or blocked outdoor condenser coil; restricted airflow over the outdoor coil; outdoor fan not running. A few things are safe to check yourself (Clear leaves, grass, and debris away from the outdoor condenser unit and make sure airflow around it is unobstructed; Replace or clean a dirty indoor air filter), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes 31 on Bryant air conditioners throughout Greater Vancouver.

Is it safe to keep running a Bryant air conditioner with a fault code?

Most Bryant fault codes put the air conditioner into a safe lockout for a reason. You can safely check the basics — the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool — and restart it once. If the code returns, stop and book a technician. Air-conditioner faults are electrical and refrigerant issues — never open the unit or touch the wiring or refrigerant lines yourself.

Bryant air conditioner repair across Greater Vancouver

HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Bryant air conditioners — sensor and thermistor errors, communication faults, fan and compressor problems, refrigerant and pressure faults, and control-board issues — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your air conditioner is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.

Need it sorted fast? We offer priority emergency air conditioner repair. Explore Air Conditioner services, browse all air conditioner error codes by brand, or request a free estimate.

Bryant air conditioner service areas

We repair Bryant air conditioners across Greater Vancouver and the Fraser Valley, including:

VancouverBurnabySurreyRichmondCoquitlamNorth VancouverWest VancouverNew WestminsterLangleyDeltaPort CoquitlamPort MoodyMaple RidgeWhite RockAbbotsfordChilliwack

Bryant air conditioner error code FAQs

Can I reset my Bryant air conditioner myself?

Yes — power-cycling the unit at the breaker once is generally safe after you’ve checked the basics (the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool). If the air conditioner faults again right away, stop and note the code — repeatedly resetting a air conditioner that keeps locking out can mask a real problem. Call a licensed HVAC technician to diagnose it.

What does the Bryant 16 code mean?

On Bryant air conditioners, 16 commonly indicates system communications failure. the outdoor control has lost communication with the evolution wall control or indoor unit. Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed HVAC technician. HeatLand fixes this across Greater Vancouver.

Do you repair Bryant air conditioners you didn’t install?

Yes. HeatLand is brand-agnostic and services Bryant air conditioners throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.

Is a Bryant air conditioner fault code an emergency?

No heat in cold weather or no cooling in a heat wave is worth treating urgently. For priority air conditioner repair across Greater Vancouver, call (604) 330-3812.

How much does Bryant air conditioner repair cost in Vancouver?

It depends on the fault. Many Bryant codes point to sensors, thermistors, capacitors or control parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.

Bryant air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Bryant air conditioners across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

More Air Conditioner error-code guides

HeatLand repairs every major air conditioner brand across Greater Vancouver. More brand guides:

Get your free estimate

Tell us what's going on and we'll get right back to you — no pressure, no obligation.

  • Free, no-obligation quotes
  • All major brands serviced
  • Metro Vancouver & the Fraser Valley
  • Financing & CleanBC rebate help