Serving Metro Vancouver & the Fraser Valley · Since 1999 info@heatland.caEmergency Service

Amana Air Conditioner Error Codes — Meanings, Causes & Repair in Greater Vancouver

Amana Air Conditioner Error Codes — Meanings, Causes & Repair in Greater Vancouver

Seeing a fault code on your Amana air conditioner? This guide explains what the most common Amana air conditioner error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed HVAC technicians for Amana air conditioner repair across Metro Vancouver and the Fraser Valley.

The codes below apply across common Amana models (ComfortNet, standard). Meanings follow Amana’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.

How to read Amana air conditioner error codes

Amana central ACs share the Goodman/Daikin platform. Basic single-stage Amana ACs (e.g. ASXC/ASX/ANX 'standard' split units) have NO on-unit fault-code display – the outdoor contactor simply energizes or not, and most AC-related faults are reported by the matched indoor air-handler or gas-furnace control board (2-character 7-segment diagnostic characters) rather than by the condenser. The premium communicating variable-speed inverter line (ComfortNet-compatible, e.g. AVXC20) shows numbered E-codes on the outdoor control-board 7-segment LED AND scrolls a plain-language ClimateTalk fault message on the ComfortNet / CTK0x communicating thermostat. Outdoor inverter faults use E-codes (E11-E55) plus Ed0-Ed3 data/configuration codes; communicating air-handler faults use 2-character codes (Ed, E5, EF, b0/b9, d0/d1, C1/C2, etc.). The board stores the six most recent system faults (7-segment Screen One / FAULT RECALL), and the ComfortNet thermostat lists recent faults under Equipment Status / Diagnostics. Codes here are from official Amana AVXC20 outdoor and AVPTC**14 air-handler service/installation manuals; meanings can vary by model and major revision.

Amana air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Amana air conditioners across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

Amana air conditioner error codes & what they mean

These are the Amana air conditioner codes our Greater Vancouver technicians see most. Anything marked pro repair involves electrical, refrigerant, sensor or control-board work that must be done by a licensed HVAC technician — never open the indoor/outdoor unit or refrigerant lines yourself.

CodeWhat it usually meansCommon causesSafe to check yourself
E11 / RUN SYS TESTThermostat/board message that the required start-up System Verification Test must be run after install or a data/board change (commissioning step, not a hardware failure) pro repairInitial system test not yet completed after installation; Control board replaced or shared data changedNo action needed by the homeowner; the installer runs the System Verification Test from the ComfortNet menu
E13 / HI PRESSURE MHigh pressure (minor) – the unit is experiencing high-pressure faults pro repairBlocked or dirty condenser coil; Service (stop) valve not fully open; Refrigerant overchargeClear leaves, grass and debris from around the outdoor condenser and keep airflow paths open; Set the thermostat to Cool and try one single power cycle at the breaker
E15 / LOW PRESSURE CLow pressure (critical) – the unit is experiencing low-pressure faults pro repairService (stop) valve not fully open; Restriction in the refrigerant lines; Low refrigerant charge / refrigerant leakReplace a dirty air filter and make sure indoor supply/return airflow is not blocked; Set the thermostat to Cool and retry once
E17 / COMPRESSOR FAILCompressor failure – the unit is experiencing frequent compressor faults pro repairService (stop) valve not fully open; Compressor wiring fault / lost phase; Compressor motor failureTry one single power cycle at the breaker
E19 / PCB OR FAN FAILOutdoor control board and/or outdoor fan motor fault pro repairObstruction in fan rotation; Outdoor fan motor not connected properly; Outdoor fan not runningCheck the outdoor fan grille for debris (leaves/branches) and clear obstructions; Try one single power cycle at the breaker
E21 / EEV CTRL FAILElectronic expansion valve (EEV) control fault pro repairEEV not connected properly; Faulty EEV or control boardNo homeowner fix; requires technician service
E22 / HI DISCH TEMPHigh discharge temperature – frequent high discharge-temperature faults pro repairDischarge thermistor inoperable or improperly positioned/connected; Low refrigerant charge or overcharge; Faulty compressorMake sure the outdoor condenser is clear of debris; Try one single power cycle at the breaker
E23 / DISCH TEMP FAILDischarge temperature sensor out of range / sensor failure pro repairDischarge thermistor inoperable or improperly connectedNo homeowner fix; requires technician sensor service
E24 / HPS OPENThe high-pressure switch is open pro repairHigh-pressure switch inoperable; Underlying high-pressure condition (dirty coil, blocked condenser, overcharge, outdoor fan not running)Clear debris from around the outdoor condenser; Set the thermostat to Cool and try one single power cycle at the breaker
E26 / PRESSURE SENSORPressure sensor not reacting properly / pressure sensor malfunction pro repairPressure sensor inoperable or not properly connectedNo homeowner fix; requires technician service
E28 / COIL TEMP FAIL2Outdoor coil temperature sensor out of range / sensor failure pro repairOutdoor coil thermistor inoperable or improperly connectedNo homeowner fix; requires technician sensor service
E29 / LIQ TEMP FAILLiquid line temperature sensor out of range / sensor failure pro repairLiquid-line thermistor inoperable or improperly connectedNo homeowner fix; requires technician sensor service
E31 / HI LEAK CURRENTHigh leakage current detected (high-voltage leakage to ground) pro repairImproper ground; Faulty compressorTurn the unit off and leave it off; this is an electrical fault – call a licensed technician
E32 / HI TEMP CTRL1High temperature fault on the outdoor control board pro repairOutdoor control board overheating; Restricted airflow around the outdoor unit electronics; Faulty control boardMake sure the outdoor unit is clear of debris and has open airflow; Try one single power cycle at the breaker
E34 / CURRENT SPIKEHigh current condition detected, indicating potential for a short circuit pro repairCurrent spike in supply; Service (stop) valve not fully open; Compressor wiring fault / lost phaseLeave the unit off; this is an electrical fault – call a licensed technician
E35 / HIGH CURRENTHigh current condition detected on the outdoor control board pro repairShort-circuit condition; Service (stop) valve not fully open; Refrigerant overchargeLeave the unit off; this is an electrical fault – call a licensed technician
E36 / STARTUP ERRORAbnormal condition detected during the compressor startup procedure pro repairService (stop) valve not fully open; Compressor or wiring problem; Faulty control boardTry one single power cycle at the breaker
E38 / COMP VOLTAGEVoltage-related issue with the compressor detected pro repairCompressor wiring fault; Supply voltage problem; Faulty control board or compressorCheck the breaker for the AC is fully ON (not tripped); Try one single power cycle at the breaker
E40 / COMP MISMATCHCompressor requirement differs from the installed compressor capability (mismatch) pro repairIncorrect shared data / configuration; Wrong board or compressor for the unitNo homeowner fix; requires technician data/configuration service
E41 / LOW REFRIGERANTControl detected a low refrigerant condition pro repairRefrigerant leak; Low refrigerant charge; Thermistors inoperable or not properly connectedNo homeowner fix; refrigerant work must be done by a licensed technician
E42 / LOW LINE VOLTControl detected a low power-supply voltage condition pro repairLow line voltage supply; Tripped breaker / blown fuse; Utility supply issueCheck the breaker for the AC is fully ON (not tripped); Try one single power cycle at the breaker
E43 / HIGH LINE VOLTControl detected a high power-supply voltage condition pro repairHigh line voltage supply; Utility supply issueNo homeowner fix; line-voltage issue requires a technician/utility
E44 / OP TEMP RANGEOutdoor temperature is outside the recommended operating range; the unit may still operate normally DIY-checkableAmbient air temperature too high or too low for normal operationWait and retry during a more moderate outdoor temperature; Try one single power cycle at the breaker
E45 / NO COOLING TESTUnable to start the cooling-mode test because indoor heat is on (commissioning message, not a failure) pro repairIndoor heat active during a technician testNo homeowner action; the technician turns off indoor heat to run the test
E47 / NO SYS VER TESTUnable to start the system verification test because indoor heat is on (commissioning message, not a failure) pro repairIndoor heat active during the system verification testNo homeowner action; the technician turns off indoor heat to run the test
E48 / NO PUMP DOWNControl unable to enter Pump Down Mode because indoor heat is on (service message, not a failure) pro repairIndoor heat active during a technician pump-down procedureNo homeowner action; technician procedure only
E49 / NO CHARGE MODEControl unable to enter Charging Mode because indoor heat is on (service message, not a failure) pro repairIndoor heat active during a technician charging procedureNo homeowner action; technician procedure only
E50 / LINE VOLT CTRLVoltage issue detected on the outdoor control board pro repairHigh or low voltage from supply; Faulty control boardCheck the breaker is fully ON; Try one single power cycle at the breaker
E51 / OD COMM ERRORCommunication issue detected by the outdoor control board (communicating/ComfortNet system) pro repairCommunication wiring disconnected or loose; Wiring damage between indoor and outdoor unitsTry one single power cycle at the breaker
E52 / COMP FAIL MINORFrequent compressor faults detected (minor) pro repairService (stop) valve not fully open; Compressor wiring issue; Compressor problemTry one single power cycle at the breaker
E54 / HI DIS TEMP MINFrequent high discharge-temperature faults (minor) pro repairDischarge thermistor problem; Low refrigerant charge or overcharge; Restricted condenser airflowMake sure the outdoor condenser is clear of debris; Try one single power cycle at the breaker
Ed0 / NO ID AIRFLOWOutdoor control sees estimated indoor airflow near 0 CFM (indoor blower not delivering airflow) pro repairIndoor blower not running; Severely restricted filter/ductwork; Communication or wiring issue with the indoor unitReplace a dirty air filter and open all supply/return vents; Try one single power cycle at the breaker
Ed1 / INVALID DATAOutdoor control board lacks the appropriate shared data needed to operate pro repairMissing or invalid shared data on the network; Communicating system not commissionedNo homeowner fix; requires technician data programming
Ed2 / INVALID SYSTEMAirflow requirement exceeds the indoor subsystem capability (system mismatch) pro repairIndoor and outdoor unit not matched for required airflow; Incorrect shared dataNo homeowner fix; requires technician configuration
Ed3 / INVALID CONFIG / INVALID MC DATAMismatch between shared data and hardware, or rejected memory-card/data-loader data pro repairShared data incompatible with the installed hardware; Data-loader/memory-card data rejected or wrongNo homeowner fix; requires technician data programming
Ed (air handler) / FUSE OPENControl fuse open on the communicating air-handler board (24V control fuse blown) pro repairBlown control-board fuse; Short in the 24V control wiring; Loose or open low-voltage connectionConfirm the outdoor disconnect and indoor breaker are ON; Set the thermostat to Cool with a low setpoint; Try one single power cycle at the breaker
EF (air handler) / BLOWER MOTOR COMMUNICATION ERRORCommunication error between the air-handler control board and the blower motor pro repairLoose or incorrect blower motor wiring; Power interruption / low voltage; Faulty control board or blower motorTry one single power cycle at the breaker
P2 (air handler) / BLOWER MOTOR NOT RUNNINGIndoor blower motor is not running pro repairFan/motor obstruction; Power interruption / low voltage; Loose or incorrect wiringCheck and replace a dirty air filter; Make sure supply and return vents are open and unblocked; Try one single power cycle at the breaker
dF (air handler) / LOW INDOOR AIRFLOWEstimated indoor airflow is lower than the airflow requirement (low indoor airflow) pro repairExcessive duct static pressure (restricted ductwork/filter); Failed indoor blower motor; Blower motor not properly connectedReplace a dirty air filter; Open all supply and return vents and clear any blockage; Make sure the return grille is not obstructed
C1 (air handler) / DATA NOT ON NETWORKThe air-handler control board does not have the shared data it needs on the network to operate pro repairNo shared data loaded on the network; Communicating system not yet commissionedNo homeowner fix; requires technician data programming
C2 (air handler) / INVALID DATA ON NETWORKInvalid shared data on the network for the air-handler control pro repairWrong or invalid shared data on the networkNo homeowner fix; requires technician data programming

Amana air conditioner codes we get called for most

E19 / PCB OR FAN FAIL — Outdoor control board and/or outdoor fan motor fault

Typical causes include obstruction in fan rotation; outdoor fan motor not connected properly; outdoor fan not running. A few things are safe to check yourself (Check the outdoor fan grille for debris (leaves/branches) and clear obstructions; Try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E19 / PCB OR FAN FAIL on Amana air conditioners throughout Greater Vancouver.

E23 / DISCH TEMP FAIL — Discharge temperature sensor out of range / sensor failure

Typical causes include discharge thermistor inoperable or improperly connected. A few things are safe to check yourself (No homeowner fix; requires technician sensor service), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E23 / DISCH TEMP FAIL on Amana air conditioners throughout Greater Vancouver.

E17 / COMPRESSOR FAIL — Compressor failure – the unit is experiencing frequent compressor faults

Typical causes include service (stop) valve not fully open; compressor wiring fault / lost phase; compressor motor failure. A few things are safe to check yourself (Try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E17 / COMPRESSOR FAIL on Amana air conditioners throughout Greater Vancouver.

E13 / HI PRESSURE M — High pressure (minor) – the unit is experiencing high-pressure faults

Typical causes include blocked or dirty condenser coil; service (stop) valve not fully open; refrigerant overcharge. A few things are safe to check yourself (Clear leaves, grass and debris from around the outdoor condenser and keep airflow paths open; Set the thermostat to Cool and try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E13 / HI PRESSURE M on Amana air conditioners throughout Greater Vancouver.

Is it safe to keep running a Amana air conditioner with a fault code?

Most Amana fault codes put the air conditioner into a safe lockout for a reason. You can safely check the basics — the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool — and restart it once. If the code returns, stop and book a technician. Air-conditioner faults are electrical and refrigerant issues — never open the unit or touch the wiring or refrigerant lines yourself.

Amana air conditioner repair across Greater Vancouver

HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Amana air conditioners — sensor and thermistor errors, communication faults, fan and compressor problems, refrigerant and pressure faults, and control-board issues — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your air conditioner is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.

Need it sorted fast? We offer priority emergency air conditioner repair. Explore Air Conditioner services, browse all air conditioner error codes by brand, or request a free estimate.

Amana air conditioner service areas

We repair Amana air conditioners across Greater Vancouver and the Fraser Valley, including:

VancouverBurnabySurreyRichmondCoquitlamNorth VancouverWest VancouverNew WestminsterLangleyDeltaPort CoquitlamPort MoodyMaple RidgeWhite RockAbbotsfordChilliwack

Amana air conditioner error code FAQs

Can I reset my Amana air conditioner myself?

Yes — power-cycling the unit at the breaker once is generally safe after you’ve checked the basics (the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool). If the air conditioner faults again right away, stop and note the code — repeatedly resetting a air conditioner that keeps locking out can mask a real problem. Call a licensed HVAC technician to diagnose it.

What does the Amana E17 / COMPRESSOR FAIL code mean?

On Amana air conditioners, E17 / COMPRESSOR FAIL commonly indicates compressor failure – the unit is experiencing frequent compressor faults. Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed HVAC technician. HeatLand fixes this across Greater Vancouver.

Do you repair Amana air conditioners you didn’t install?

Yes. HeatLand is brand-agnostic and services Amana air conditioners throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.

Is a Amana air conditioner fault code an emergency?

No heat in cold weather or no cooling in a heat wave is worth treating urgently. For priority air conditioner repair across Greater Vancouver, call (604) 330-3812.

How much does Amana air conditioner repair cost in Vancouver?

It depends on the fault. Many Amana codes point to sensors, thermistors, capacitors or control parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.

Amana air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Amana air conditioners across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

More Air Conditioner error-code guides

HeatLand repairs every major air conditioner brand across Greater Vancouver. More brand guides:

Get your free estimate

Tell us what's going on and we'll get right back to you — no pressure, no obligation.

  • Free, no-obligation quotes
  • All major brands serviced
  • Metro Vancouver & the Fraser Valley
  • Financing & CleanBC rebate help
Prefer to talk now? Call (604) 330-3812

We'll only use your details to contact you about your request.