Seeing a fault code on your Goodman air conditioner? This guide explains what the most common Goodman air conditioner error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed HVAC technicians for Goodman air conditioner repair across Metro Vancouver and the Fraser Valley.
The codes below apply across common Goodman models (ComfortNet, standard). Meanings follow Goodman’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.
How to read Goodman air conditioner error codes
Standard single-stage Goodman ACs have NO on-unit fault display; the contactor simply energizes or not, and most diagnostics appear on the indoor air-handler/furnace control board. Communicating variable-speed inverter ACs (ComfortNet-compatible GVXC/GVZC family) show a 7-segment LED diagnostic code on the control board AND scroll a plain-language fault message on the ComfortNet / CTK04 communicating thermostat (Climate Talk message). Outdoor inverter faults use E-codes (e.g. E13, E24, E51); indoor air-handler faults use 2-character 7-segment codes (e.g. E5, b0, b9, d0). Stored faults are retrieved via the FAULT RECALL button on the board (last 6 faults) or the thermostat Equipment Status / Diagnostics screen.
Goodman air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Goodman air conditioners across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairGoodman air conditioner error codes & what they mean
These are the Goodman air conditioner codes our Greater Vancouver technicians see most. Anything marked pro repair involves electrical, refrigerant, sensor or control-board work that must be done by a licensed HVAC technician — never open the indoor/outdoor unit or refrigerant lines yourself.
| Code | What it usually means | Common causes | Safe to check yourself |
|---|---|---|---|
| E5 (indoor board) / E_E5 BLOWN FUSE | Fuse open on the indoor air-handler control board (24V control fuse blown) pro repair | Blown control-board fuse (F1U); Short in 24V control wiring; Open connector / loose low-voltage connection | Confirm the outdoor disconnect and indoor breaker are ON; Set the thermostat to Cool with a low setpoint; Try one single power cycle at the breaker |
| EE / no display (EMG mode) / INTERNAL FAULT | Internal control fault or no power to the indoor blower control board pro repair | No 208/230V or 24V power to the blower/control board; Blown fuse or tripped circuit breaker; Short in 208/230V or 24V circuit | Check the indoor and outdoor breakers are ON; Confirm the furnace/air-handler power switch is ON; Try one single power cycle at the breaker |
| EF / E_EF AUXILIARY SWITCH OPEN | Auxiliary/safety switch open on the air handler (e.g. condensate float switch tripped) pro repair | High water level in the evaporator drain pan (clogged condensate drain); Connected alarm device activated; Auxiliary alarm terminals open | Check for standing water near the indoor unit and a backed-up condensate drain; Set thermostat to Cool and retry after clearing any obvious drain blockage at the pan if safely accessible |
| b0 (Eb0) / NO ID AIRFLOW / Blower Motor Not Running | Indoor blower motor not running / estimated indoor airflow near 0 CFM pro repair | Fan/motor obstruction; Power interruption / low voltage; Incorrect or loose wiring | Check and replace a dirty air filter; Make sure supply and return vents are open and unblocked; Try one single power cycle at the breaker |
| b1 (E_b1) / Blower Communication Error | Communication error between the control board and the blower motor pro repair | Incorrect or loose wiring; Power interruption / low voltage; Faulty control board or motor | Try one single power cycle at the breaker |
| b9 (Eb9) / LOW ID AIRFLOW | Estimated indoor airflow is lower than the airflow requirement (low indoor airflow, minor code) pro repair | Too much static pressure (restricted ductwork/filter); Failed indoor blower motor; Blower motor not properly connected | Replace a dirty air filter; Open all supply and return vents and clear any blockage; Make sure the return grille is not obstructed |
| d0 (E_d0) / NO NET DATA / Ed0 | Control board does not have the shared data it needs on the network to operate pro repair | No shared data loaded on the network; Communicating system not yet commissioned | No homeowner fix; requires technician data programming |
| d1 (E_d1) / INVALID DATA / Ed1 | Invalid shared data on the network for the control module pro repair | Wrong shared data on the network; Network data invalid for the control module | No homeowner fix; requires technician data programming |
| E13 | High pressure (critical) – equipment experiencing frequent high-pressure faults pro repair | Blocked/restricted condenser coil or lines; Service (stop) valve not fully open; Refrigerant overcharge | Clear leaves, grass and debris from around the outdoor condenser and keep it free of obstructions; Set thermostat to Cool and try one single power cycle at the breaker |
| E15 | Low pressure (critical) – equipment experiencing frequent low-pressure faults pro repair | Service (stop) valve not fully open; Restriction in refrigerant lines; Low refrigerant charge / refrigerant leak | Replace a dirty air filter and make sure indoor airflow is not blocked; Set thermostat to Cool and retry once |
| E17 | Compressor fail – equipment experiencing frequent compressor faults pro repair | Service (stop) valve not fully open; Compressor wire lost phase / wiring issue; Compressor motor failure | Try one single power cycle at the breaker |
| E19 | PCB or fan fail – frequent outdoor control board and/or fan motor faults pro repair | Obstruction in fan rotation; Outdoor fan motor not properly connected; Outdoor fan not running | Check the outdoor fan grille for debris (leaves/branches) and clear obstructions; Try one single power cycle at the breaker |
| E22 | High discharge temperature – frequent high discharge-temperature faults; discharge thermistor may be misplaced pro repair | Discharge thermistor inoperable or improperly connected/positioned; Low refrigerant charge or overcharge; Faulty compressor | Make sure the outdoor condenser is clear of debris; Try one single power cycle at the breaker |
| E23 | Discharge temperature sensor fail – discharge temperature sensor out of range pro repair | Discharge thermistor inoperable or improperly connected | No homeowner fix; requires technician sensor service |
| E24 | HPS open – the high-pressure switch is open pro repair | High-pressure switch inoperable; Condition that caused high pressure (dirty coil, blocked condenser, overcharge) | Clear debris from around the outdoor condenser; Try one single power cycle at the breaker |
| E25 / AIR SENSOR FLT | Outdoor air temperature sensor is open or shorted pro repair | Faulty outdoor thermistor sensor or disconnected sensor | No homeowner fix; requires technician sensor service |
| E26 / PRESSURE SENSOR | Pressure sensor not reacting properly pro repair | Low-pressure sensor inoperable or not properly connected | No homeowner fix; requires technician service |
| E31 / HI LEAK CURRENT | Control detected high leakage current (high-voltage leakage to ground) pro repair | Improper ground; Faulty compressor | Turn the unit off and leave it off; this is an electrical fault – call a licensed technician |
| E34 / CURRENT SPIKE | High current condition detected, indicating potential for a short circuit pro repair | Current spike in supply; Service (stop) valve not fully open; Compressor wire lost phase | Leave the unit off; this is an electrical fault – call a licensed technician |
| E35 / HIGH CURRENT | High current condition detected on the outdoor control board pro repair | Short-circuit condition; Service (stop) valve not fully open; Refrigerant overcharge | Leave the unit off; this is an electrical fault – call a licensed technician |
| E41 / LOW REFRIGERANT | Control detected a low refrigerant condition pro repair | Refrigerant leak; Low refrigerant charge; Thermistors inoperable or not properly connected | No homeowner fix; refrigerant work must be done by a licensed technician |
| E42 / LOW LINE VOLT | Control detected a low power-supply voltage condition pro repair | Low line voltage supply; Tripped breaker / blown fuse; Utility supply issue | Check the breaker for the AC is fully ON (not tripped); Try one single power cycle at the breaker |
| E43 / HIGH LINE VOLT | Control detected a high power-supply voltage condition pro repair | High line voltage supply; Utility supply issue | No homeowner fix; line-voltage issue requires a technician/utility |
| E44 / OP TEMP RANGE | Outdoor temperature is outside the recommended operating range; unit may still operate normally DIY-checkable | Ambient air temperature too high or too low for normal operation | Wait and retry during a more moderate outdoor temperature; Try one single power cycle at the breaker |
| E50 / LINE VOLT CTRL | Voltage issue on the outdoor control board pro repair | High or low voltage from supply; Faulty control board | Check the breaker is fully ON; Try one single power cycle at the breaker |
| E51 / OD COMM ERROR | Communication issue detected by the outdoor control board (communicating/ComfortNet system) pro repair | Communication wiring disconnected or loose | Try one single power cycle at the breaker |
| E11 / RUN SYS TEST | Thermostat message indicating the required start-up System Verification Test must be run (commissioning step, not a failure) pro repair | Initial system test not yet completed after install or board/data change | No action needed by homeowner; the installer runs the System Verification Test from the ComfortNet menu |
| Ed0 / D1 INVALID DATA / D2 INVALID SYSTEM / D3 INVALID CONFIG / D4 INVALID MC DATA (outdoor) | Outdoor control board shared-data / configuration faults (no data, invalid data, airflow mismatch, hardware mismatch, or rejected data loader data) pro repair | Outdoor unit shared data missing, invalid, or incompatible with the system; Communication wiring loose; Data loader (BTSDL01) data rejected or wrong | No homeowner fix; requires technician data programming |
Goodman air conditioner codes we get called for most
E5 (indoor board) / E_E5 BLOWN FUSE — Fuse open on the indoor air-handler control board (24V control fuse blown)
Typical causes include blown control-board fuse (f1u); short in 24v control wiring; open connector / loose low-voltage connection. A few things are safe to check yourself (Confirm the outdoor disconnect and indoor breaker are ON; Set the thermostat to Cool with a low setpoint), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E5 (indoor board) / E_E5 BLOWN FUSE on Goodman air conditioners throughout Greater Vancouver.
E22 — High discharge temperature – frequent high discharge-temperature faults; discharge thermistor may be misplaced
Typical causes include discharge thermistor inoperable or improperly connected/positioned; low refrigerant charge or overcharge; faulty compressor. A few things are safe to check yourself (Make sure the outdoor condenser is clear of debris; Try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E22 on Goodman air conditioners throughout Greater Vancouver.
d1 (E_d1) / INVALID DATA / Ed1 — Invalid shared data on the network for the control module
Typical causes include wrong shared data on the network; network data invalid for the control module. A few things are safe to check yourself (No homeowner fix; requires technician data programming), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes d1 (E_d1) / INVALID DATA / Ed1 on Goodman air conditioners throughout Greater Vancouver.
E13 — High pressure (critical) – equipment experiencing frequent high-pressure faults
Typical causes include blocked/restricted condenser coil or lines; service (stop) valve not fully open; refrigerant overcharge. A few things are safe to check yourself (Clear leaves, grass and debris from around the outdoor condenser and keep it free of obstructions; Set thermostat to Cool and try one single power cycle at the breaker), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E13 on Goodman air conditioners throughout Greater Vancouver.
Is it safe to keep running a Goodman air conditioner with a fault code?
Most Goodman fault codes put the air conditioner into a safe lockout for a reason. You can safely check the basics — the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool — and restart it once. If the code returns, stop and book a technician. Air-conditioner faults are electrical and refrigerant issues — never open the unit or touch the wiring or refrigerant lines yourself.
Goodman air conditioner repair across Greater Vancouver
HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Goodman air conditioners — sensor and thermistor errors, communication faults, fan and compressor problems, refrigerant and pressure faults, and control-board issues — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your air conditioner is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.
Need it sorted fast? We offer priority emergency air conditioner repair. Explore Air Conditioner services, browse all air conditioner error codes by brand, or request a free estimate.
Goodman air conditioner service areas
We repair Goodman air conditioners across Greater Vancouver and the Fraser Valley, including:
Goodman air conditioner error code FAQs
Can I reset my Goodman air conditioner myself?
Yes — power-cycling the unit at the breaker once is generally safe after you’ve checked the basics (the power and breaker on, the air filter clean, the outdoor condenser clear of debris, and the thermostat set to cool). If the air conditioner faults again right away, stop and note the code — repeatedly resetting a air conditioner that keeps locking out can mask a real problem. Call a licensed HVAC technician to diagnose it.
What does the Goodman b1 (E_b1) / Blower Communication Error code mean?
On Goodman air conditioners, b1 (E_b1) / Blower Communication Error commonly indicates communication error between the control board and the blower motor. Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed HVAC technician. HeatLand fixes this across Greater Vancouver.
Do you repair Goodman air conditioners you didn’t install?
Yes. HeatLand is brand-agnostic and services Goodman air conditioners throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.
Is a Goodman air conditioner fault code an emergency?
No heat in cold weather or no cooling in a heat wave is worth treating urgently. For priority air conditioner repair across Greater Vancouver, call (604) 330-3812.
How much does Goodman air conditioner repair cost in Vancouver?
It depends on the fault. Many Goodman codes point to sensors, thermistors, capacitors or control parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.
Goodman air conditioner acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Goodman air conditioners across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairMore Air Conditioner error-code guides
HeatLand repairs every major air conditioner brand across Greater Vancouver. More brand guides:
Amana air conditioner codes
41 Amana air conditioner fault codes — meanings, causes & repair.
Daikin air conditioner codes
35 Daikin air conditioner fault codes — meanings, causes & repair.
Rheem air conditioner codes
45 Rheem air conditioner fault codes — meanings, causes & repair.
Lennox air conditioner codes
33 Lennox air conditioner fault codes — meanings, causes & repair.
Carrier air conditioner codes
29 Carrier air conditioner fault codes — meanings, causes & repair.
Bryant air conditioner codes
26 Bryant air conditioner fault codes — meanings, causes & repair.