The pressure switch is a safety device that confirms the draft inducer fan is creating proper negative pressure before allowing the furnace to ignite. When it fails, the furnace will not progress past the pre-ignition stage.
HeatLand Heating & Cooling provides expert furnace diagnosis across Greater Vancouver.
Call (604) 330-3812 Get a Free QuoteWhat This Symptom Means
A furnace with a pressure switch fault will typically start the draft inducer, run it briefly, then lock out — often displaying a specific blink code. The furnace cannot safely ignite without confirmed draft, so the pressure switch prevents the gas valve from opening.
Common Causes
- Blocked or kinked pressure switch hose (rubber tubing connecting switch to inducer housing)
- Condensate in the pressure switch tubing blocking the port
- Failed pressure switch diaphragm no longer responding to pressure changes
- Draft inducer running but not generating enough negative pressure
- Blocked flue or venting reducing draft
- Cracked inducer housing affecting pressure readings
What Homeowners Can Check Safely
- Check furnace blink code on door label — pressure switch faults are commonly coded as 2–3 specific blinks
- Look at the rubber hose connected to the draft inducer assembly — visible cracks or kinks are a sign
- Listen — can you hear the draft inducer fan spin up for a few seconds before lockout?
When to Call a Licensed Technician
Some furnace issues require a licensed HVAC technician. Do not attempt to open gas lines, replace internal components, or reset persistent lockouts without professional diagnosis.
- Pressure switch testing with a manometer
- Hose inspection and clearing of condensate blockage
- Draft inducer performance testing
- Flue and vent inspection for blockage
- Pressure switch replacement if diaphragm has failed
Frequently Asked Questions
What does a furnace pressure switch do exactly?
It monitors the negative pressure (suction) created by the draft inducer fan. If the inducer is running and pulling air through the combustion chamber at the correct rate, the switch closes and signals the control board to proceed with ignition. If the pressure is wrong — because the inducer is weak, the flue is blocked, or the hose is kinked — the switch stays open and the furnace locks out.
Can a blocked pressure switch hose cause furnace lockout?
Yes, and it is one of the most common causes of pressure switch faults. Condensate from a high-efficiency furnace can collect in the small hose connecting the switch to the inducer housing. Blowing out the hose or clearing the blockage often resolves the fault without needing to replace the switch itself.
If your furnace is showing these signs, HeatLand can help. We serve homeowners across Greater Vancouver.
Call (604) 330-3812 Book a Furnace Check