Seeing a fault code on your Heil furnace? This guide explains what the most common Heil furnace error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed, TSBC-certified gas technicians for Heil furnace repair across Metro Vancouver and the Fraser Valley.
The codes below apply across common Heil models (ION, standard ICP). Meanings follow Heil’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.
How to read Heil furnace error codes
Diagnostic LED on the integrated furnace control (visible through a sight glass on the blower door). The LED is read by its state and flash count: a steady-on or off pattern indicates power/lockout status, while a repeating number of amber/red flashes (with a brief pause between groups) maps to a fault. A continuous slow flash means a call for heat is being served normally; a 'heartbeat' (1 flash per second) means power is present with no call for heat. Some two-stage and variable-speed (ION) controls also display two-part combination codes shown as a short flash group, pause, then a second group (for example 4 flashes, pause, 2 flashes = '4+2'). Codes are also printed on the SERVICE/wiring label inside the blower compartment.
Heil furnace acting up in Metro Vancouver? HeatLand’s licensed, TSBC-certified gas technicians diagnose and repair Heil furnaces across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairHeil furnace error codes & what they mean
These are the Heil furnace codes our Greater Vancouver technicians see most. Anything marked pro repair involves gas, electrical, sealed-combustion or control-board work that must be done by a licensed gas technician (TSBC-certified in BC) — never open gas or electrical components yourself.
| Code | What it usually means | Common causes | Safe to check yourself |
|---|---|---|---|
| LED Off | No power to the control board (no 24V / no line power reaching the control) pro repair | Furnace disconnect switch off; Tripped breaker or blown fuse; Blown low-voltage (3A) fuse on the control board | Confirm the furnace power switch (looks like a light switch on or near the furnace) is ON; Check the breaker labeled for the furnace and reset it once if tripped; Make sure the blower access door is fully closed and seated so the door switch engages |
| LED On, steady (not flashing) | Control circuit lockout / internal control fault — the board has detected a hard fault and is not flashing a numbered code pro repair | Internal control board malfunction; Control hardware/firmware fault requiring replacement or a power reset | Set the thermostat to OFF, then to HEAT, and confirm it is calling for heat; Try a single power cycle at the furnace switch or breaker to clear a temporary lockout; If the steady light returns, stop and call a licensed technician |
| LED On, continuous slow flashing | Normal operation with an active call for heat — no fault DIY-checkable | This is the expected indication during a normal heating cycle | No action needed; this indicates normal operation |
| LED On, 'heartbeat' (1 flash per second) | Normal operation, no call for heat — the control has 24V power and is idle/healthy DIY-checkable | This is the expected indication when the furnace is powered but not heating | No action needed; this indicates the control is powered and healthy; If you expect heat, set the thermostat to HEAT and above room temperature |
| 2 flashes | Pressure switch did not open — the control sensed the pressure switch was already closed when it should have been open at the start of the cycle pro repair | Pressure switch stuck closed; Defective pressure switch; Obstruction or moisture in the pressure tubing | Go outside and confirm nothing is leaning against or blocking the intake and exhaust vent terminals; clear leaves, snow, ice, or debris; Try a single power cycle at the furnace switch |
| 3 flashes | Pressure switch did not close, or reopened during the cycle — the control did not see proper draft proving pro repair | Blocked or restricted vent / improper vent sizing; Excessive wind affecting the vent; Defective inducer (draft) motor | Check that outdoor intake and exhaust vent terminals are clear of snow, ice, leaves, or nests; Confirm nothing has been leaned against the vent pipes outside; Try a single power cycle at the furnace switch |
| 4 flashes | Limit circuit fault / limit circuit open — a safety limit (overheat) switch has opened pro repair | Dirty or clogged air filter restricting airflow; Restricted ductwork or closed/blocked registers; Loose blower wheel or defective blower motor | Check the air filter and replace it if it is dirty or clogged; Make sure supply and return air registers/vents are open and not blocked by furniture or rugs; Confirm the return-air grille is not obstructed |
| 5 flashes | Abnormal flame-proving signal — flame was sensed when the gas valve was commanded off pro repair | Leaky gas valve; Gas valve stuck open; Defective control board sensing circuit | This is a gas-safety fault — do not attempt repairs; Set the thermostat to OFF and call a licensed HVAC technician |
| 6 flashes | Failure to ignite, or flame was lost (flame signal weak or non-existent) while running pro repair | Dirty or oxidized flame sensor; Defective or worn hot-surface igniter; Low inlet gas pressure or gas supply interruption | Confirm the gas supply is on and other gas appliances (stove, water heater) are working; Make sure the gas shutoff valve at the furnace is in the open position; Try a single power cycle at the furnace switch to allow one more ignition attempt |
| 7 flashes | Limit circuit lockout — repeated limit/overheat trips have locked the control out; it auto-resets after about 3 hours pro repair | Persistent airflow restriction (see code 4 causes); Dirty filter, restricted ducts, or failing blower | Check and replace a dirty air filter; Confirm registers and the return-air grille are open and unobstructed; Try a single power cycle to clear the lockout instead of waiting for the 3-hour auto-reset |
| 8 flashes | Gas heating lockout — the control will not auto-reset; power must be cycled to clear pro repair | Miswired gas valve; Defective gas valve / control valve; Repeated ignition or flame faults reaching lockout | Confirm the gas supply is on and other gas appliances work; Try a single power cycle at the furnace switch to clear the lockout; If it returns, call a licensed technician |
| 9 flashes | Medium-pressure switch, high-pressure switch, or PSR relay did not close or has reopened (two-stage / high-efficiency models). Diagnose using the same approach as code 3 pro repair | Restricted or improperly sized vent; Clogged condensate drain; Defective pressure switch or PSR relay | Check that outdoor intake/exhaust vent terminals are clear of snow, ice, and debris; Try a single power cycle at the furnace switch |
| 10 flashes | Line voltage polarity reversed (or polarity/grounding fault) — the control requires correct line-voltage polarity to operate pro repair | Reversed line (hot) and neutral wiring; Open or poor equipment ground; Burnt wiring harness or damaged spot on the control board | This is an electrical wiring fault — do not open wiring; Set the thermostat to OFF and call a licensed HVAC technician |
| 1+2 (1 flash, pause, 2 flashes) | Blower is energized after a normal power-up / blower-on indication — generally a normal status, not a hard fault DIY-checkable | Normal control behavior after power is applied or a cycle ends | Usually normal; no action needed; If the blower runs continuously and unexpectedly, set the thermostat fan setting to AUTO |
| 1+5 (1 flash, pause, 5 flashes) | Blower motor lockout — the control auto-resets after about 3 hours pro repair | Failed or seized blower motor; Blower motor wiring fault; Control unable to confirm blower operation | Try a single power cycle at the furnace switch to clear the lockout; If it returns, call a licensed technician |
| 3+5 (3 flashes, pause, 5 flashes) | Gas valve fault — a problem with the gas valve circuit (often associated with the valve wiring such as the red/yellow/orange leads) pro repair | Gas valve wiring fault; Defective gas valve; Defective control board valve circuit | This is a gas-valve fault — do not attempt repairs; Set the thermostat to OFF and call a licensed HVAC technician |
| 4+1 (4 flashes, pause, 1 flash) | Blower motor fault — the blower failed to reach its expected speed (for example failed to reach about 250 RPM) pro repair | Failing or obstructed blower motor; Blower wheel obstruction or imbalance; Motor control / wiring fault | Check the air filter and replace if dirty; Confirm registers and the return grille are not blocked; Try a single power cycle at the furnace switch |
| 4+2 (4 flashes, pause, 2 flashes) | Inducer (draft) motor fault — the inducer did not operate within expected parameters pro repair | Improper vent sizing or restricted vent; Failed or failing inducer motor; Wiring fault to the inducer | Check that outdoor intake/exhaust vent terminals are clear of snow, ice, and debris; Try a single power cycle at the furnace switch |
| 4+3 (4 flashes, pause, 3 flashes) | Low/medium pressure switch open while the medium/high pressure switch is closed (two-stage high-efficiency draft fault) pro repair | Low gas pressure; Clogged condensate drain; Stuck or defective pressure switch | Check outdoor vent terminals are clear of snow, ice, and debris; Confirm the gas supply is on and other gas appliances work; Try a single power cycle at the furnace switch |
| 6+1 (6 flashes, pause, 1 flash) | Ignition lockout — too many failed ignition attempts; the control auto-resets after about 3 hours (diagnose using code 6) pro repair | Dirty or oxidized flame sensor; Worn or defective hot-surface igniter; Low inlet gas pressure or gas interruption | Confirm the gas supply is on and other gas appliances work; Make sure the furnace gas shutoff valve is open; Try a single power cycle at the furnace switch to allow another ignition attempt instead of waiting 3 hours |
Heil furnace codes we get called for most
6+1 (6 flashes, pause, 1 flash) — Ignition lockout — too many failed ignition attempts; the control auto-resets after about 3 hours (diagnose using code 6)
Typical causes include dirty or oxidized flame sensor; worn or defective hot-surface igniter; low inlet gas pressure or gas interruption. A few things are safe to check yourself (Confirm the gas supply is on and other gas appliances work; Make sure the furnace gas shutoff valve is open), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 6+1 (6 flashes, pause, 1 flash) on Heil furnaces throughout Greater Vancouver.
2 flashes — Pressure switch did not open — the control sensed the pressure switch was already closed when it should have been open at the start of the cycle
Typical causes include pressure switch stuck closed; defective pressure switch; obstruction or moisture in the pressure tubing. A few things are safe to check yourself (Go outside and confirm nothing is leaning against or blocking the intake and exhaust vent terminals; clear leaves, snow, ice, or debris; Try a single power cycle at the furnace switch), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 2 flashes on Heil furnaces throughout Greater Vancouver.
4 flashes — Limit circuit fault / limit circuit open — a safety limit (overheat) switch has opened
Typical causes include dirty or clogged air filter restricting airflow; restricted ductwork or closed/blocked registers; loose blower wheel or defective blower motor. A few things are safe to check yourself (Check the air filter and replace it if it is dirty or clogged; Make sure supply and return air registers/vents are open and not blocked by furniture or rugs), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 4 flashes on Heil furnaces throughout Greater Vancouver.
1+2 (1 flash, pause, 2 flashes) — Blower is energized after a normal power-up / blower-on indication — generally a normal status, not a hard fault
Typical causes include normal control behavior after power is applied or a cycle ends. A few things are safe to check yourself (Usually normal; no action needed; If the blower runs continuously and unexpectedly, set the thermostat fan setting to AUTO), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 1+2 (1 flash, pause, 2 flashes) on Heil furnaces throughout Greater Vancouver.
Is it safe to keep running a Heil furnace with a fault code?
Most Heil fault codes put the furnace into a safe lockout for a reason. You can safely check the basics — the furnace switch and breaker on, a clean air filter, the gas supply on, the thermostat set to heat and calling, and — on high-efficiency models — the condensate drain not blocked or frozen — and restart it once. If the code returns, stop and book a technician. If you ever smell gas, leave the building and call your gas utility’s emergency line or 911 first. If a carbon-monoxide alarm sounds, get everyone out and call 911. A rollout or repeated limit trip can signal a heat-exchanger or venting problem — don’t keep resetting it.
Heil furnace repair across Greater Vancouver
HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Heil furnaces — ignition and flame-sensor faults, pressure-switch and venting problems, limit and rollout trips, blower and igniter issues, and control-board errors — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your furnace is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.
Need it sorted fast? We offer priority emergency furnace repair. Explore Furnace services, browse all furnace error codes by brand, or request a free estimate.
Heil furnace service areas
We repair Heil furnaces across Greater Vancouver and the Fraser Valley, including:
Heil furnace error code FAQs
Can I reset my Heil furnace myself?
Yes — power-cycling the reset button once is generally safe after you’ve checked the basics (the furnace switch and breaker on, a clean air filter, the gas supply on, the thermostat set to heat and calling, and — on high-efficiency models — the condensate drain not blocked or frozen). If the furnace faults again right away, stop and note the code — repeatedly resetting a furnace that keeps locking out can mask a real problem. Call a licensed, TSBC-certified gas technician to diagnose it.
What does the Heil 6+1 (6 flashes, pause, 1 flash) code mean?
On Heil furnaces, 6+1 (6 flashes, pause, 1 flash) commonly indicates ignition lockout — too many failed ignition attempts; the control auto-resets after about 3 hours (diagnose using code 6). Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed, TSBC-certified gas technician. HeatLand fixes this across Greater Vancouver.
Do you repair Heil furnaces you didn’t install?
Yes. HeatLand is brand-agnostic and services Heil furnaces throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.
Is a Heil furnace fault code an emergency?
No heat in cold weather is worth treating urgently. If you ever smell gas, leave the building and call your gas utility’s emergency line or 911 first. If a carbon-monoxide alarm sounds, get everyone out and call 911. A rollout or repeated limit trip can signal a heat-exchanger or venting problem — don’t keep resetting it. For priority furnace repair across Greater Vancouver, call (604) 330-3812.
How much does Heil furnace repair cost in Vancouver?
It depends on the fault. Many Heil codes point to sensors, ignition or pump parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.
Heil furnace acting up in Metro Vancouver? HeatLand’s licensed, TSBC-certified gas technicians diagnose and repair Heil furnaces across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairMore Furnace error-code guides
HeatLand repairs every major furnace brand across Greater Vancouver. More brand guides:
Tempstar furnace codes
20 Tempstar furnace fault codes — meanings, causes & repair.
Lennox furnace codes
50 Lennox furnace fault codes — meanings, causes & repair.
Daikin furnace codes
36 Daikin furnace fault codes — meanings, causes & repair.
Goodman furnace codes
32 Goodman furnace fault codes — meanings, causes & repair.
Rheem furnace codes
30 Rheem furnace fault codes — meanings, causes & repair.
Amana furnace codes
25 Amana furnace fault codes — meanings, causes & repair.