Trane Heat Pump Error Codes — Meanings, Causes & Repair in Greater Vancouver

Trane Heat Pump Error Codes — Meanings, Causes & Repair in Greater Vancouver

Seeing a fault code on your Trane heat pump? This guide explains what the most common Trane heat pump error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed HVAC technicians for Trane heat pump repair across Metro Vancouver and the Fraser Valley.

The codes below apply across common Trane models (ComfortLink II, XV, XR). Meanings follow Trane’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.

How to read Trane heat pump error codes

Trane communicating heat pumps (ComfortLink II / AccuLink, e.g. XV20i, XV18, XL18i) report alphanumeric alert codes in the form CL2.NNN.NN on the ComfortLink II thermostat (XL850/XL950/XL1050), with certain conditions also shown as a short 'ERR NN' message. The same fault on the outdoor control board is indicated by a red Fault LED flash count. The variable-speed inverter compressor 'Drive' has its own CL2.176-186 fault family. Basic single-stage units (e.g. XR14, XR15) are NON-communicating: they have no thermostat display and most show only a red outdoor-board status LED (or no diagnostic display at all). Sister brand American Standard uses the identical control platform and the same codes. Source: Trane ComfortLink II Service Facts (Pub. D802247P01) and Trane ComfortLink II Alert Codes master list.

Trane heat pump acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Trane heat pumps across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

Trane heat pump error codes & what they mean

These are the Trane heat pump codes our Greater Vancouver technicians see most. Anything marked pro repair involves electrical, refrigerant, sensor or control-board work that must be done by a licensed HVAC technician — never open the indoor/outdoor unit or refrigerant lines yourself.

CodeWhat it usually meansCommon causesSafe to check yourself
CL2.067.00 / 5 Flash / Fault A inputsAmbient (outdoor air) temperature sensor fault — out of range, open or shorted. A working ambient sensor is required for defrost, low-pressure monitoring and Charge Assist, so loss of it can disable heat-pump heating/defrost pro repairFailed outdoor ambient temperature sensor; Open or shorted sensor wiring/connector; Corroded connector at the outdoor control boardConfirm the outdoor unit disconnect and breaker are ON; Try one thermostat restart (switch the system Off, wait a minute, then back to Heat or Cool)
CL2.067.01 / 6 FlashCoil temperature sensor fault — out of range, open or shorted. The outdoor coil sensor governs defrost timing, so a fault can cause poor heating or defrost problems pro repairFailed outdoor coil temperature sensor; Open or shorted sensor wiring; Sensor not clipped to the coilConfirm the outdoor disconnect and breaker are ON; Clear snow, ice, leaves and debris from around the outdoor unit; Try one thermostat restart
CL2.067.02 / 11 FlashLiquid (line) temperature sensor fault — out of range, open or shorted pro repairFailed liquid-line temperature sensor; Open or shorted sensor wiring/connectorConfirm the outdoor disconnect and breaker are ON; Try one thermostat restart
CL2.068.00 / 2 Flash (Defrost Fault A)Defrost Fault A — low delta-T / low heat-pump capacity detected during the heating/defrost logic. Often points to a charge, airflow, sensor or reversing-valve issue pro repairReversing (switch-over) valve stuck in heat mode; Outdoor fan failure; Low refrigerant chargeClear ice, snow, leaves and debris from the outdoor coil and fan; Confirm nothing is blocking outdoor airflow and the unit has clearance; Check and replace a dirty indoor air filter
CL2.068.01 / 3 Flash (Defrost Fault B and/or C)Defrost Fault B and/or C — very high delta-T, or defrost terminated at least 10 times in a row on the 15-minute maximum override time instead of by temperature pro repairOpen coil sensor; Shorted ambient air sensor; Reversing valve not switching correctlyClear ice, snow and debris from the outdoor coil; Confirm the outdoor disconnect and breaker are ON; Try one thermostat restart
CL2.068.02 / 4 Flash (Defrost Fault A and [B/C])Combined Defrost Fault A and (B and/or C) — 60 or more A faults together with one or more B or C faults (repeated low-delta-T defrosts plus time-terminated defrosts) pro repairReversing valve stuck or sluggish; Low refrigerant charge; Outdoor fan or airflow problemClear ice, snow and debris from the outdoor coil and fan; Check and replace a dirty indoor air filter; Confirm the outdoor disconnect and breaker are ON
CL2.079.00 (LPCO Short Lock-Out)Low-pressure cut-out open — short lock-out (about 5 minutes). Low suction pressure has tripped the switch; on the third short lock-out the control issues a hard lock-out and the thermostat shows ERR 79 pro repairLow refrigerant charge; Refrigerant restriction; Indoor airflow restriction (cooling) — dirty filter or coilCheck and replace a dirty indoor air filter; Confirm supply/return vents are open and unobstructed; Clear ice, snow and debris from the outdoor unit
CL2.079.02 / 7 Flash / ERR 79 (LPCO Hard Lock-Out)Low-pressure cut-out hard lock-out (Heat/Cool lockout) — low suction pressure tripped repeatedly; cycle power to reset. Note: a brief power interruption to the outdoor unit can also cause ERR 79 to display pro repairLow refrigerant charge; Indoor airflow restriction (cooling); Outdoor airflow restriction / iced coil (heating)Check and replace a dirty indoor air filter; Clear ice, snow and debris from the outdoor unit; Confirm the outdoor disconnect and breaker are ON
CL2.080.00 / 17 Flash / ERR 80 (HPCO Short Lock-Out)High-pressure switch tripped — High Pressure short lock-out (HPCO limit = 650 psig). System pressure exceeded the safe limit pro repairRefrigerant overcharge; Outdoor fan failure or outdoor airflow restriction (cooling); Indoor blower failure or indoor airflow restriction (heating)Check and replace a dirty indoor air filter; Clear leaves, snow and debris from the outdoor unit and confirm the fan can spin freely (power off); Confirm supply/return vents are open
CL2.080.01 (HPCO Hard Lock-Out)High-pressure hard lock-out — 6 High-Pressure short lock-out events have occurred (High-Pressure limit = 650 psig). Requires power cycle and diagnosis pro repairRefrigerant overcharge; Outdoor fan failure / airflow restriction (cooling); Indoor blower failure / airflow restriction (heating)Check and replace a dirty indoor air filter; Clear debris from the outdoor unit; Confirm the outdoor disconnect and breaker are ON
CL2.090.02 / 1 Flash (Alert 90)System communication error / CRC — excessive communication errors; the comfort control is continually trying to communicate with no idle detected (bus busy) pro repairR and B (or D and B) data wiring reversed at the thermostat or indoor unit; Faulty communicating accessory on the bus (e.g. air cleaner); Loose or damaged communication (D/B) wiringConfirm the thermostat has power and its display is normal; Try one thermostat restart (power cycle at the breaker)
CL2.091.00 / 1 Flash / ERR 91 (Blower Comm / Loss of Demand)Communication fault — loss of communication between control boards (e.g. blower/inducer to control board), or loss of the heat/cool demand message between the thermostat and equipment pro repairLoss of low-voltage communication between indoor and outdoor control boards; Reversed or disconnected D/B data wiring; Power glitch affecting the low-voltage circuitConfirm the thermostat is powered and displaying normally; Confirm the indoor and outdoor disconnects/breakers are ON; Try one thermostat restart
CL2.089.00 / CL2.089.01 (Config Fault — Equipment Missing)Configuration fault — equipment that was auto-discovered at start-up is no longer reporting on the communication bus. Often appears after a power outage if a unit drops off the bus pro repairCommunication wiring fault (12 VDC = good, 16 VDC = loss of communication between D & B); Outdoor or indoor unit lost power; Loose data-wire connectionConfirm both indoor and outdoor disconnects/breakers are ON; Try one thermostat restart after restoring power
CL2.092.00 (Check Fuse)Check Fuse — the 24 V fuse on the control board is open. The board Status LED is also lit solid when this condition exists pro repairHigh amp draw in the low-voltage circuit; Shorted low-voltage field wiring; High resistance in field wiringConfirm the thermostat is unresponsive/blank (a sign of a blown low-voltage fuse); Confirm the system breaker is ON
CL2.102.00 / 10 Flash (Y2 No Y1)Y2 (second-stage) demand present without Y1 (first-stage) — a miswire condition (24-volt mode). Indicates Y1 and Y2 field wiring reversed pro repairY1 and Y2 thermostat/field wiring reversed; Wiring error after a thermostat changeConfirm the system breaker is ON; Try one thermostat restart
CL2.113.00 / 12 Flash / ERR 113 (Liquid Pressure Sensor Fault)Liquid pressure sensor fault — sensor shorted (0 VDC), open (4.99 VDC) or out of range; or no output voltage from the control board pro repairFailed liquid pressure transducer; Open or shorted sensor wiring; Control-board output voltage missingConfirm the outdoor disconnect and breaker are ON; Try one thermostat restart
CL2.114.00 / 14 Flash / ERR 114 (Personality Module Fault)Personality Module (PM) data fault — the primary PM data file is corrupt (system may keep running on a stored local copy, with the fault displayed on the user interface) pro repairCorrupted Personality Module (power surge); PM damaged by faulty field wiring; PM needs replacementConfirm the system breaker is ON; Try one thermostat restart
CL2.114.01 (Capacity Mismatch)Personality Module fault — the outdoor-unit tonnage stored in the outdoor PM does not match the indoor PM capacity range. System runs but flags a mismatch; usually means outdoor and indoor units are not a rated match pro repairOutdoor unit not an AHRI-rated match with the indoor unit; Wrong Personality Module installedNo homeowner action — record the code for your technician
CL2.155.00 / .01 / .02 (EEV Motor Fault)Electronic Expansion Valve (EEV) motor fault — the EEV motor fault was detected 8 consecutive times, or the EEV motor winding/coil is open, shorted or intermittently shorted pro repairEEV motor windings or connecting harness bad; EEV coil open or shortedConfirm the outdoor disconnect and breaker are ON; Try one thermostat restart
CL2.174.00 (Suction Pressure Sensor Fault)Suction pressure sensor fault — the suction pressure sensor input is shorted or out of range. (On the EEV control board this also corresponds to a 3-flash 'Suction Pressure Transducer out of range' indication.) pro repairFailed suction pressure transducer; Open or shorted sensor wiring; No control-board output voltage to the sensorConfirm the outdoor disconnect and breaker are ON; Try one thermostat restart
CL2.175.00 / .01 (Limp Mode)Limp-along mode — the variable-speed compressor speed is limited to a constant value (or compressor operation is inhibited) because of a sensor loss (dome, suction, ambient or indoor sensor) or a refrigerant-pressure/airflow problem pro repairOne or more sensors faulted/out of range (dome, suction, ambient, indoor); Refrigerant pressure or airflow problem; Low chargeCheck and replace a dirty indoor air filter; Clear debris from the outdoor unit; Confirm the outdoor disconnect and breaker are ON
CL2.176.00 (Drive Comm Lockout)Modbus communication failure — loss of internal communication within the variable-speed compressor Drive. On a persistent 176.00, cycling power to the outdoor unit is advised; if it returns the Drive needs replacement pro repairInternal Drive communication fault; Electromagnetic interference (EMI) source; Failed compressor DriveTry one single power cycle of the outdoor unit at the breaker; Confirm the outdoor disconnect and breaker are ON
CL2.177.xx (Drive Current Failure)Variable-speed Drive current fault — the Drive output current is too high, triggering internal derate or a current cut-out (software or hardware). Repeated occurrences cause a lockout pro repairHigh load: refrigerant overcharge, dirty coils, low airflow or air recirculation; Compressor fault (locked rotor or shorted windings); Drive hardware failureCheck and replace a dirty indoor air filter; Clear leaves, snow and debris from the outdoor coil; Confirm nothing is recirculating hot air around the unit
CL2.178.00 / .01 / .02 (DC Voltage Failure)Variable-speed Drive DC-bus voltage fault — DC bus over 480 VDC (high cut-out) or under 220 VDC (low cut-out); 10 consecutive high cut-outs cause an excessive-overvoltage lockout pro repairLow or unstable line voltage (verify supply 187–253 VAC); PFC / Drive hardware failureConfirm the outdoor disconnect and breaker are ON; Try one single power cycle
CL2.179.xx (Power Module Temperature Failure)Variable-speed Drive power-module over-temperature — rectifier or inverter temperature exceeded the derate or shutdown threshold, so the compressor is derated or stopped pro repairHigh load condition; Heat-sink performance loss / Drive cooling problem; Drive hardware failureClear debris from the outdoor unit so it can cool; Check and replace a dirty indoor air filter; Confirm the outdoor disconnect and breaker are ON
CL2.180.02 (Low Voltage Cut-Out)Supply voltage failure — supply voltage is less than 175 VAC, causing the Drive to cut out (with derating below 200 VAC) pro repairLow incoming line voltage / utility brown-out; Loose or undersized power wiring; Disconnect or breaker problemConfirm the outdoor disconnect and breaker are fully ON; Try one single power cycle once normal power is confirmed
CL2.181.01 / .03 (Reverse Rotation Protection)Reverse-rotation protection (soft/hard lock-out) — at start-up the suction pressure did not drop in the allotted time, so the compressor cannot start; 5 such shutdowns escalate to a hard lock-out. Often a reversing-valve (SOV) or compressor-pumping problem pro repairReversing/switch-over valve (SOV) bypassing; Compressor miswired; Suction pressure sensor failureConfirm the outdoor disconnect and breaker are ON; Try one single power cycle
CL2.181.02 (Motor Phase Loss)Motor phase-loss protection — a compressor cable connection or motor winding problem (a missing phase to the compressor) pro repairLoose or damaged compressor cable connection; Compressor motor winding problem; Drive faultConfirm the outdoor disconnect and breaker are ON; Try one single power cycle
CL2.181.04 (Stall Detection)Stall detection — a locked-rotor condition has been detected on the variable-speed compressor pro repairLocked-rotor compressor; Grossly overcharged system or closed service valves; Drive hardware failureConfirm the outdoor disconnect and breaker are ON; Try one single power cycle
CL2.181.09 (No Motor)No motor detected — the compressor motor is not detected (all three windings missing), usually a disconnected or open compressor cable pro repairCompressor cable missing or unplugged; All compressor windings open/shorted; Drive faultConfirm the outdoor disconnect and breaker are ON; Try one single power cycle to see if the alert clears
EEV Fault LED 6 Flash (board-level)On the Electronic Expansion Valve control board, 6 red flashes = the valve is not responding to a position-change command (possible stuck EEV valve). Requires additional diagnostics pro repairStuck EEV valve; EEV motor/coil or harness faultConfirm the outdoor disconnect and breaker are ON; Try one single power cycle
EEV Fault LED 8 Flash (board-level)On the EEV control board, 8 red flashes = the compressor is not pumping (verify with superheat/pressure diagnostics per Service Facts) pro repairCompressor not pumping; Low charge or restriction; Reversing valve bypassingConfirm the outdoor disconnect and breaker are ON; Clear debris from the outdoor unit
Outdoor board LED 3 Flash (status, not a fault)On legacy non-communicating outdoor boards, a 3-flash status indicates the unit is in an active defrost cycle — this is NORMAL operation (steam/vapor off the outdoor coil is expected), not a failure DIY-checkableNormal cold-weather defrost cycleNo action needed — allow the unit to finish defrosting and resume heating

Trane heat pump codes we get called for most

CL2.067.00 / 5 Flash / Fault A inputs — Ambient (outdoor air) temperature sensor fault — out of range, open or shorted. A working ambient sensor is required for defrost, low-pressure monitoring and Charge Assist, so loss of it can disable heat-pump heating/defrost

Typical causes include failed outdoor ambient temperature sensor; open or shorted sensor wiring/connector; corroded connector at the outdoor control board. A few things are safe to check yourself (Confirm the outdoor unit disconnect and breaker are ON; Try one thermostat restart (switch the system Off, wait a minute, then back to Heat or Cool)), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes CL2.067.00 / 5 Flash / Fault A inputs on Trane heat pumps throughout Greater Vancouver.

CL2.091.00 / 1 Flash / ERR 91 (Blower Comm / Loss of Demand) — Communication fault — loss of communication between control boards (e.g. blower/inducer to control board), or loss of the heat/cool demand message between the thermostat and equipment

Typical causes include loss of low-voltage communication between indoor and outdoor control boards; reversed or disconnected d/b data wiring; power glitch affecting the low-voltage circuit. A few things are safe to check yourself (Confirm the thermostat is powered and displaying normally; Confirm the indoor and outdoor disconnects/breakers are ON), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes CL2.091.00 / 1 Flash / ERR 91 (Blower Comm / Loss of Demand) on Trane heat pumps throughout Greater Vancouver.

CL2.155.00 / .01 / .02 (EEV Motor Fault) — Electronic Expansion Valve (EEV) motor fault — the EEV motor fault was detected 8 consecutive times, or the EEV motor winding/coil is open, shorted or intermittently shorted

Typical causes include eev motor windings or connecting harness bad; eev coil open or shorted. A few things are safe to check yourself (Confirm the outdoor disconnect and breaker are ON; Try one thermostat restart), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes CL2.155.00 / .01 / .02 (EEV Motor Fault) on Trane heat pumps throughout Greater Vancouver.

Is it safe to keep running a Trane heat pump with a fault code?

Most Trane fault codes put the heat pump into a safe lockout for a reason. You can safely check the basics — the power and breaker on, the indoor filter clean, the outdoor unit clear of snow, ice and debris, and the remote set to the correct mode and temperature — and restart it once. If the code returns, stop and book a technician. Mini-split and heat-pump faults are electrical and refrigerant issues — never open the indoor or outdoor unit, and never touch the wiring or refrigerant lines yourself.

Trane heat pump repair across Greater Vancouver

HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Trane heat pumps — sensor and thermistor errors, indoor-to-outdoor communication faults, fan and compressor problems, refrigerant and pressure faults, and control-board issues — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your heat pump is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.

Need it sorted fast? We offer priority emergency heat pump repair. Explore Heat Pump services, browse all heat pump error codes by brand, or request a free estimate.

Trane heat pump service areas

We repair Trane heat pumps across Greater Vancouver and the Fraser Valley, including:

VancouverBurnabySurreyRichmondCoquitlamNorth VancouverWest VancouverNew WestminsterLangleyDeltaPort CoquitlamPort MoodyMaple RidgeWhite RockAbbotsfordChilliwack

Trane heat pump error code FAQs

Can I reset my Trane heat pump myself?

Yes — power-cycling the unit at the breaker once is generally safe after you’ve checked the basics (the power and breaker on, the indoor filter clean, the outdoor unit clear of snow, ice and debris, and the remote set to the correct mode and temperature). If the heat pump faults again right away, stop and note the code — repeatedly resetting a heat pump that keeps locking out can mask a real problem. Call a licensed HVAC technician to diagnose it.

What does the Trane CL2.067.00 / 5 Flash / Fault A inputs code mean?

On Trane heat pumps, CL2.067.00 / 5 Flash / Fault A inputs commonly indicates ambient (outdoor air) temperature sensor fault — out of range, open or shorted. a working ambient sensor is required for defrost, low-pressure monitoring and charge assist, so loss of it can disable heat-pump heating/defrost. Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed HVAC technician. HeatLand fixes this across Greater Vancouver.

Do you repair Trane heat pumps you didn’t install?

Yes. HeatLand is brand-agnostic and services Trane heat pumps throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.

Is a Trane heat pump fault code an emergency?

No heat in cold weather or no cooling in a heat wave is worth treating urgently. For priority heat pump repair across Greater Vancouver, call (604) 330-3812.

How much does Trane heat pump repair cost in Vancouver?

It depends on the fault. Many Trane codes point to sensors, thermistors, capacitors or control parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.

Trane heat pump acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Trane heat pumps across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

More Heat Pump error-code guides

HeatLand repairs every major heat pump brand across Greater Vancouver. More brand guides:

Get your free estimate

Tell us what's going on and we'll get right back to you — no pressure, no obligation.

  • Free, no-obligation quotes
  • All major brands serviced
  • Metro Vancouver & the Fraser Valley
  • Financing & CleanBC rebate help
Prefer to talk now? Call (604) 330-3812

We'll only use your details to contact you about your request.