Serving Metro Vancouver & the Fraser Valley · Since 1999 info@heatland.caEmergency Service

Rinnai Boiler Error Codes — Meanings, Causes & Repair in Greater Vancouver

Rinnai Boiler Error Codes — Meanings, Causes & Repair in Greater Vancouver

Seeing a fault code on your Rinnai boiler? This guide explains what the most common Rinnai boiler error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed, TSBC-certified gas technicians for Rinnai boiler repair across Metro Vancouver and the Fraser Valley.

The codes below apply across common Rinnai models (Sensei, i-Series, M-Series). Meanings follow Rinnai’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.

How to read Rinnai boiler error codes

Rinnai displays a one- or two-character numeric diagnostic code (e.g. 10, 11, 12, 14, 16, 25, 61, 71) on the temperature/operation controller or, on some older models, flashed on the clock display. A few alpha codes are also used: LC / LC0-LC9 (and '00' when reviewing maintenance history) for heat-exchanger scale, FF for a maintenance/service placeholder, SE/SS for service-reminder indicators. The same numeric scheme is shared across Rinnai tankless water heaters (SENSEI, SENSEI RX/CX, and Non-SENSEI series) and Rinnai I-Series / M-Series condensing combi boilers; exact applicability and a handful of descriptions vary by series and model.

Rinnai boiler acting up in Metro Vancouver? HeatLand’s licensed, TSBC-certified gas technicians diagnose and repair Rinnai boilers across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

Rinnai boiler error codes & what they mean

These are the Rinnai boiler codes our Greater Vancouver technicians see most. Anything marked pro repair involves gas, electrical, sealed-combustion or control-board work that must be done by a licensed gas technician (TSBC-certified in BC) — never open gas or electrical components yourself.

CodeWhat it usually meansCommon causesSafe to check yourself
02No burner operation during freeze protection (burner failed to fire when freeze-protection heating was called for) pro repairgas valve closed or low gas supply; air not purged from gas lines; igniter or flame-rod faultconfirm the gas supply shutoff valve is open and other gas appliances work; confirm the unit has power; press the ON/OFF button to reset once
03Power interruption during bath fill pro repairloss of electrical power mid-cycle; bypass flow control device fault (SENSEI); wiring faultconfirm the unit has power and the breaker is on; press the ON/OFF button to reset once
05Bypass flow control device fault pro repairfaulty bypass valve / bypass flow control device; scale or debris restriction; blocked air filter or vent (RH180)confirm the unit has power; press the ON/OFF button to reset once
07Circulation flow rate below 2.1 GPM pro repairwater supply off or low inlet pressure; pump not operating or wiring fault; clogged inlet water filterconfirm the water supply is turned on; confirm the unit has power; press the ON/OFF button to reset once
10Air supply or exhaust blockage, or condensate trap is full pro repairblocked or restricted intake/exhaust venting; clogged or frozen condensate line/trap (condensing models); dirty inlet air filtercheck that the intake and exhaust vent terminals outside are clear of snow, ice, leaves, lint or nests; confirm the condensate drain line is not clogged or frozen; confirm the unit has power
11No ignition (unit failed to establish a flame) pro repairgas valve closed or no/low gas supply; air in the gas lines; faulty igniter or flame rodconfirm the gas supply shutoff valve is open and other gas appliances in the home work; if on propane, confirm there is fuel in the tank; confirm the unit has power
12Flame failure (flame went out during operation) pro repairinterrupted or low gas supply; dirty or loose flame rod; loose ground wireconfirm the gas supply is on and other gas appliances work; if on propane, confirm there is fuel in the tank; check that the outside vent terminals are clear
13Combustion abnormality (improper combustion detected) pro repairrestricted air supply or venting; incorrect gas pressure or gas-type setting; debris in burner / heat exchangercheck that the intake/exhaust vent terminals outside are clear; confirm the inlet air filter area is unobstructed; press the ON/OFF button to reset once
14Thermal fuse, overheat sensor (ODS) or heat-exchanger overheat (high-temperature shutdown) pro repairheat exchanger overheating due to scale build-up or restricted water flow; blocked venting / combustion fault; locked-up boiler pump or closed CH valves (combi)for combi boilers, confirm the system water pressure gauge reads in the normal range and isolation valves are open; check that the outside vent terminals are clear; press the ON/OFF (or reset) button once
15Venturi control fault (venturi operation error) pro repairfaulty venturi motor; gas valve / venturi assembly fault; wiring faultpress the ON/OFF (or reset) button once
16High outgoing water temperature (outlet water too hot – safety shutdown) pro repairscale build-up restricting flow; faulty outgoing-water thermistor; gas valve or orifice issueconfirm the water supply is on and not restricted; press the ON/OFF (or reset) button once
17Venturi blockage pro repairdebris/blockage in the venturi or silencer; blocked condensate drain; vent connection or venting faultconfirm the condensate drain line is not clogged or frozen; check that the outside vent terminals are clear; press the ON/OFF (or reset) button once
18Gas valve adjustment limit reached pro repairgas pressure out of range; gas valve / combustion calibration fault; incorrect gas-type or altitude settingconfirm the gas supply is on and other gas appliances work; press the ON/OFF button to reset once
19Electrical grounding fault (unit not properly earthed) pro repairmissing or poor electrical ground / bonding; faulty or miswired power supply; loose ground wire at the PC boardconfirm the unit is plugged in / has power on a properly grounded circuit; press the ON/OFF button to reset once
21Data transfer error (PC board / parameter mismatch) pro repaircontrol board replaced without completing data transfer; parameters not programmed correctly for the model; wiring faultpress the ON/OFF button to reset once
22Gas valve adjustment fault (reed switch on gas valve) pro repairmisaligned or faulty reed switch on the gas valve; gas valve fault; wiring faultpress the ON/OFF button to reset once
25Condensate safety (float) switch tripped – condensate backed up pro repairclogged or frozen condensate drain line; condensate pump not working; condensate trap blockedconfirm the condensate drain line is not clogged or frozen; press the ON/OFF button to reset once
30Flammable vapor sensor activated pro repairflammable vapors (gasoline, solvents, paint, aerosols) near the unit; faulty flammable vapor sensorremove any gasoline, solvents, paints, aerosols or other flammable liquids/vapors from near the unit and ventilate the area; press the ON/OFF button to reset once
31Burner thermocouple fault pro repairfaulty or disconnected burner thermocouple; wiring fault; control board faultpress the ON/OFF button to reset once
32Outgoing water temperature thermistor fault (open/short or scaled) pro repairdisconnected or faulty outgoing-water thermistor; scale build-up on the thermistor; wiring open/shortpress the ON/OFF button to reset once
33Heat exchanger thermistor fault (open/short) pro repairdisconnected or faulty heat-exchanger thermistor; wiring open/short; control board faultpress the ON/OFF button to reset once
34Combustion air temperature thermistor fault pro repairdisconnected or faulty combustion-air thermistor; wiring open/short; control board faultpress the ON/OFF button to reset once
35Tank temperature sensor fault pro repairdisconnected or faulty tank temperature sensor; wiring open/short; control board faultpress the ON/OFF button to reset once
38Exhaust gas temperature sensor fault (or CO sensor fault on RH180) pro repairfaulty exhaust gas temperature sensor (or CO sensor on RH180); wiring fault; control board faultpress the ON/OFF button to reset once
41Freeze protection sensor fault (external/outdoor sensor) pro repairdisconnected, cut or shorted freeze-protection sensor/thermistor; sensor covered with insulation; wiring faultpress the ON/OFF button to reset once
51Inlet (incoming) water temperature thermistor fault pro repairdisconnected or faulty inlet-water thermistor; scale build-up on the sensor; wiring open/shortpress the ON/OFF button to reset once
52Solenoid (gas) valve circuit fault pro repairfaulty gas solenoid valve or wiring; loose/damaged flame-rod or solenoid harness; moisture on connectionspress the ON/OFF button to reset once
54High exhaust gas temperature (exhaust temperature exceeded limit) pro repairscale build-up in the heat exchanger (hard water); improper venting or vent restriction; exhaust thermistor faultcheck that the outside vent terminals are clear; press the ON/OFF button to reset once
57Burner overheat bi-metal switch tripped pro repairburner area overheating; faulty bi-metal overheat switch; restricted air/combustioncheck that the outside vent terminals are clear; press the ON/OFF button to reset once
58Secondary heat exchanger sensor fault pro repairfaulty or disconnected secondary heat-exchanger sensor; wiring fault; control board faultpress the ON/OFF button to reset once
61Combustion fan motor fault pro repairseized or failing fan motor; debris obstructing the fan wheel; loose or damaged fan wiring harnesscheck that the outside intake/exhaust vent terminals are clear of debris; press the ON/OFF button to reset once
63Recirculation low flow / recirculation pump fault pro repairincorrect recirculation DIP/parameter setting; clogged inlet or bypass filter; air in the recirculation lineconfirm the unit has power; press the ON/OFF button to reset once
65Water flow control device (servo valve) fault pro repairfaulty water flow control / servo valve; moisture on the harness or connector; wiring faultpress the ON/OFF button to reset once
66Bypass flow servo (bypass flow control device) fault pro repairfaulty bypass flow servo / bypass valve; moisture on the harness or connector; wiring faultpress the ON/OFF button to reset once
70PC board (control board) fault pro repaircontrol board circuit fault; incorrect parameter settings; loose/damaged wiring at the PC boardpress the ON/OFF button to reset once
71Gas solenoid valve circuit (control signal) fault pro repairDIP switch set incorrectly; loose or damaged gas-control / solenoid wiring; control board faultpress the ON/OFF button to reset once
72Flame rod (flame sensing) fault pro repairflame rod not contacting the flame; carbon build-up on the flame rod; wet or damaged flame rod / wiringpress the ON/OFF button to reset once
73Burner thermocouple fault pro repairfaulty or disconnected burner thermocouple; loose/damaged wiring; control board faultpress the ON/OFF button to reset once
79Water leakage detected pro repairinternal water leak detected by the leak sensor; faulty fitting, heat exchanger or connection leak; faulty leak sensorlook for visible water around or under the unit; if water is present, shut off the water supply to the unit and call a technician; press the ON/OFF button to reset once only if no leak is found
FEFlammable vapors detected pro repairflammable vapors (gasoline, solvents, paint, aerosols) near the unit; faulty flammable vapor sensorremove any gasoline, solvents, paints, aerosols or other flammable liquids/vapors from near the unit and ventilate the area; press the ON/OFF button to reset once
FFMaintenance/service placeholder (indicates a service provider performed maintenance; not a fault) DIY-checkableentered by a technician after performing service – this is a record marker, not a malfunctionno action needed – this is a maintenance-history marker, not an error
SEService reminder indicator (SENSEI series) DIY-checkablemaintenance/service interval reached (informational reminder set during installation)no immediate action needed – this is a service reminder; schedule routine maintenance with a technician
SSTime-based service indicator (also shown as code 55) set at installation DIY-checkablescheduled-maintenance time interval reached (informational reminder configured at installation)no immediate action needed – this is a service reminder; schedule routine maintenance with a technician
LC / LC0-LC9 / 00Scale (lime) build-up in the heat exchanger – flush required (shown as '00' when reviewing maintenance history) pro repairmineral/lime scale build-up in the heat exchanger from hard water; lack of periodic flushing/descaling; untreated hard waterno homeowner-safe internal fix – the heat exchanger must be flushed/descaled by a technician; if you are on hard water, ask about water treatment to prevent recurrence

Rinnai boiler codes we get called for most

11 — No ignition (unit failed to establish a flame)

Typical causes include gas valve closed or no/low gas supply; air in the gas lines; faulty igniter or flame rod. A few things are safe to check yourself (confirm the gas supply shutoff valve is open and other gas appliances in the home work; if on propane, confirm there is fuel in the tank), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 11 on Rinnai boilers throughout Greater Vancouver.

12 — Flame failure (flame went out during operation)

Typical causes include interrupted or low gas supply; dirty or loose flame rod; loose ground wire. A few things are safe to check yourself (confirm the gas supply is on and other gas appliances work; if on propane, confirm there is fuel in the tank), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 12 on Rinnai boilers throughout Greater Vancouver.

03 — Power interruption during bath fill

Typical causes include loss of electrical power mid-cycle; bypass flow control device fault (sensei); wiring fault. A few things are safe to check yourself (confirm the unit has power and the breaker is on; press the ON/OFF button to reset once), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 03 on Rinnai boilers throughout Greater Vancouver.

14 — Thermal fuse, overheat sensor (ODS) or heat-exchanger overheat (high-temperature shutdown)

Typical causes include heat exchanger overheating due to scale build-up or restricted water flow; blocked venting / combustion fault; locked-up boiler pump or closed ch valves (combi). A few things are safe to check yourself (for combi boilers, confirm the system water pressure gauge reads in the normal range and isolation valves are open; check that the outside vent terminals are clear), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 14 on Rinnai boilers throughout Greater Vancouver.

Is it safe to keep running a Rinnai boiler with a fault code?

Most Rinnai fault codes put the boiler into a safe lockout for a reason. You can safely check the basics — gas supply on, power on, the thermostat calling for heat, system pressure in the normal range, and the condensate drain not frozen or blocked (a common cause in Vancouver cold snaps) — and restart it once. If the code returns, stop and book a technician. If you ever smell gas, leave the building and call your gas utility’s emergency line or 911 first. If a carbon-monoxide alarm sounds, get everyone out and call 911.

Rinnai boiler repair across Greater Vancouver

HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Rinnai boilers — ignition faults, flame and sensor errors, low-pressure and pump problems, fan and flue faults, and control-board issues — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your boiler is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.

Need it sorted fast? We offer priority emergency boiler repair. Explore Boiler services, browse all boiler error codes by brand, or request a free estimate.

Rinnai boiler service areas

We repair Rinnai boilers across Greater Vancouver and the Fraser Valley, including:

VancouverBurnabySurreyRichmondCoquitlamNorth VancouverWest VancouverNew WestminsterLangleyDeltaPort CoquitlamPort MoodyMaple RidgeWhite RockAbbotsfordChilliwack

Rinnai boiler error code FAQs

Can I reset my Rinnai boiler myself?

Yes — power-cycling the reset button once is generally safe after you’ve checked the basics (gas supply on, power on, the thermostat calling for heat, system pressure in the normal range, and the condensate drain not frozen or blocked (a common cause in Vancouver cold snaps)). If the boiler faults again right away, stop and note the code — repeatedly resetting a boiler that keeps locking out can mask a real problem. Call a licensed, TSBC-certified gas technician to diagnose it.

What does the Rinnai 11 code mean?

On Rinnai boilers, 11 commonly indicates no ignition (unit failed to establish a flame). Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed, TSBC-certified gas technician. HeatLand fixes this across Greater Vancouver.

Do you repair Rinnai boilers you didn’t install?

Yes. HeatLand is brand-agnostic and services Rinnai boilers throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.

Is a Rinnai boiler fault code an emergency?

No heat in cold weather is worth treating urgently. If you ever smell gas, leave the building and call your gas utility’s emergency line or 911 first. If a carbon-monoxide alarm sounds, get everyone out and call 911. For priority boiler repair across Greater Vancouver, call (604) 330-3812.

How much does Rinnai boiler repair cost in Vancouver?

It depends on the fault. Many Rinnai codes point to sensors, ignition or pump parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.

Rinnai boiler acting up in Metro Vancouver? HeatLand’s licensed, TSBC-certified gas technicians diagnose and repair Rinnai boilers across Greater Vancouver — including units we didn’t install.

Call (604) 330-3812Get a free repair estimateNo heat? Emergency repair

More Boiler error-code guides

HeatLand repairs every major boiler brand across Greater Vancouver. More brand guides:

Get your free estimate

Tell us what's going on and we'll get right back to you — no pressure, no obligation.

  • Free, no-obligation quotes
  • All major brands serviced
  • Metro Vancouver & the Fraser Valley
  • Financing & CleanBC rebate help
Prefer to talk now? Call (604) 330-3812