Seeing a fault code on your Noritz water heater? This guide explains what the most common Noritz water heater error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed, TSBC-certified gas technicians for Noritz water heater repair across Metro Vancouver and the Fraser Valley.
The codes below apply across common Noritz models (NRC, NRCP, EZ). Meanings follow Noritz’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.
How to read Noritz water heater error codes
1-3 digit numeric code shown on the remote controller (e.g. 11, 16, 29, 90); some appear with an 'F' prefix or as a flashing code. Older non-condensing models can map the same number to a slightly different fault, so always confirm against the manual for the specific model.
Noritz water heater acting up in Metro Vancouver? HeatLand’s licensed, TSBC-certified gas technicians diagnose and repair Noritz water heaters across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairNoritz water heater error codes & what they mean
These are the Noritz water heater codes our Greater Vancouver technicians see most. Anything marked pro repair involves gas, electrical, sealed-combustion or control-board work that must be done by a licensed gas technician (TSBC-certified in BC) — never open gas or electrical components yourself.
| Code | What it usually means | Common causes | Safe to check yourself |
|---|---|---|---|
| 10 | Combustion abnormality / BTU (input) drop. The unit detects reduced combustion output but keeps running. Effectively a soft warning of insufficient firing pro repair | Insufficient gas supply or pressure; Partial venting/air-intake restriction; Dirty or debris-loaded burner, fan, or heat exchanger over time | Confirm gas is on and other gas appliances run normally; Confirm the air intake and exhaust vent terminations outside are clear of snow, leaves, or debris; Perform a single power reset (off/on) if the manual allows |
| 11 | Ignition failure – the unit failed to detect a flame at ignition (no successful light-off) pro repair | No/insufficient gas (empty propane tank, gas valve closed, low pressure); Air or restriction in the gas line; Airflow / vent blockage | Confirm the gas supply is on and another gas appliance lights normally; For propane, confirm the tank is not empty; Confirm the intake and exhaust vent terminations outside are clear |
| 12 | Flame loss – the burner lit but the flame went out (could not stay lit) during operation pro repair | Low propane tank volume or undersized gas supply; Poor / dropping gas pressure that weakens the flame; Vent or air-supply disturbance | Confirm the gas supply is on and other gas appliances run without sputtering; For propane, confirm the tank level is adequate; Confirm vent terminations are clear |
| 14 | Thermal fuse failure / overheat-prevention device (thermal fuse around the heat exchanger) has triggered due to an overheat condition pro repair | Heat exchanger overheating; Scale buildup in the heat exchanger restricting flow; Blocked or restricted water flow | Confirm the water supply to the unit is fully on and not throttled; Perform a single power reset to see if the fault clears |
| 16 | Abnormally high outlet water temperature – the outlet temperature spiked to an unsafe/scalding level, so the unit shut the burner down pro repair | Scale buildup in the heat exchanger; Low/insufficient water flow; Clogged inlet water filter screen | Confirm the cold-water supply valve to the unit is fully open; Check the inlet water filter screen for debris and clean it per the owner manual if you are comfortable doing so; Perform a single power reset |
| 20 | High-limit switch triggered (over-temperature safety). On some condensing models also associated with a clogged condensate container pro repair | Overheat condition; Scale buildup / restricted flow; Clogged inlet filter screen | Confirm the water supply is fully on; Clean the inlet water filter screen per the owner manual if comfortable; Perform a single power reset |
| 29 | Condensate drainage problem – condensate collector / neutralizer high water level. The unit cannot drain condensate, so it stops the burner to avoid flooding it. Condensing models only pro repair | Blocked condensate drain line; Clogged neutralizer; Incorrectly piped drain line (upward slope, trapped, or wrong size) | Look for an obviously kinked, frozen, or blocked external condensate drain line; Perform a single power reset after any obvious external blockage is cleared |
| 31 | Thermistor – cold water (inlet) abnormality. The inlet water temperature sensor reads out of range, open, or shorted pro repair | Loose or damaged thermistor connection / wire harness; Failed inlet thermistor | Perform a single power reset to see if it was a transient fault |
| 32 | Thermistor – hot water (outlet) abnormality. The outlet water temperature sensor reads out of range, open, or shorted pro repair | Loose or damaged thermistor connection / wire harness; Failed outlet thermistor | Perform a single power reset to see if it was a transient fault |
| 33 | Thermistor – heat exchanger outlet abnormality. The heat-exchanger temperature sensor reads out of range, open, or shorted pro repair | Loose or damaged thermistor connection / wire harness; Failed heat exchanger thermistor | Perform a single power reset to see if it was a transient fault |
| 45 | Water leak detected inside the unit (moisture/water sensed internally). Noted for NRCP and CB (Pro Series / premix) models pro repair | Internal water leak; Condensation/moisture intrusion inside the cabinet | Look for visible water pooling under or around the outside of the unit; Shut off the water supply and contact a licensed technician if a leak is visible |
| 51 | Gas solenoid valve failure (failure of the gas solenoid valve other than its drive circuit) pro repair | Faulty gas solenoid valve; Damaged or loose gas solenoid valve connection / wiring | Perform a single power reset; if the code returns, stop and call a technician |
| 61 | Fan (combustion blower) motor abnormality – the fan is not spinning, or spinning much faster/slower than the expected RPM for the current stage pro repair | Failed or obstructed fan motor; Loose fan wiring / wire harness; Temporary vent blockage (wind gusts, obstruction) | Confirm the intake and exhaust vent terminations outside are clear; Perform a single power reset; an EC61 that only shows in history may have been a transient vent/voltage event |
| 65 | Main water control servo abnormality (main flow-control valve). On non-Pro models stated as a heat-exchanger flow control valve abnormality pro repair | Failed, stuck, or debris-fouled main water servo / flow control valve; Loose servo wiring / wire harness | Perform a single power reset (power off then on) which is the documented first step for this code |
| 66 | Bypass water control servo abnormality (bypass flow-control valve) pro repair | Failed, stuck, or debris-fouled bypass water servo / bypass valve; Loose servo wiring / wire harness | Perform a single power reset (power off then on) which is the documented first step for this code |
| 71 | Gas valve abnormality – the circuit board cannot properly operate the gas valve and gas solenoids pro repair | Power supplied from a non-pure-sine-wave source (some battery backup / solar inverters); Electrical interference from other appliances on the same circuit; Failed circuit board components | Confirm the unit is plugged into a standard, dedicated household outlet (not shared with noisy appliances or a non-pure-sine inverter); Perform a single power reset |
| 72 | Flame rod circuit abnormality – the flame-sensing (flame rod) circuit is reading a fault, for example sensing a flame when the gas valve is closed pro repair | Flame rod or its wiring shorted/grounded; Circuit board fault on the flame-sensing circuit | Perform a single power reset; if the code returns, call a technician |
| 73 | Circuit board setting abnormality – usually appears when dip switches or connectors were changed while the unit had power pro repair | Dip switches or connectors changed while powered; Incorrect circuit board / dip switch configuration | Perform a single power reset (unplug, wait, restore power) – this is the documented recovery for a 73 caused by a powered change |
| 90 | Combustion abnormality – the air-to-fuel mixture is off specification (unit shuts off). Often raised after the unit repeatedly cannot hit set temperature or the fan speed is over-correcting pro repair | Insufficient gas pressure; Incorrect or poorly installed venting / wrong dip-switch settings (new installs); Dirty internal components, clogged intake/filter, or blocked exhaust termination (older units) | Confirm gas is on and other gas appliances run normally; Confirm the front-cover intake, and the intake/exhaust vent terminations outside, are clear of debris; Clean the internal air filter screen per the owner manual if you are comfortable doing so |
| 92 | Neutralizer life-cycle warning (first warning) – the neutralizer cartridge is nearing end of life and should be replaced. The unit still operates. Condensing models pro repair | Neutralizer media approaching the end of its rated service life | No homeowner check needed beyond noting the warning; schedule neutralizer replacement with a licensed technician |
| 93 | Neutralizer life-cycle end of life – the neutralizer has reached the end of its rated life and must be replaced. Condensing models pro repair | Neutralizer media fully expended | No homeowner check; arrange neutralizer replacement with a licensed technician |
| 94 | Exhaust temperature too high – the exhaust/flue temperature exceeded the allowable limit pro repair | Scale buildup in the heat exchanger; Restricted water flow; Combustion/venting issue raising flue temperature | Confirm the water supply is fully on; Confirm exhaust vent terminations are clear; Perform a single power reset |
| 99 | Combustion abnormality (unit shuts off) – abnormal combustion detected, commonly tied to a flue blockage or obstruction pro repair | Blocked or obstructed flue / exhaust venting; Abnormal combustion / air-fuel issue | Confirm the exhaust and intake vent terminations outside are clear of obstruction; Perform a single power reset (power off then on); if it returns, call a technician |
| 760 | Remote controller transmission abnormality – a communication fault between the remote controller and the unit's circuit board pro repair | Loose, damaged, or shorted remote-controller wiring; Multiple remote controllers wired incorrectly; Circuit board communication fault | Perform a single power reset to see if communication re-establishes |
| F76 | Multi-system communication error – a communication fault between multiple quick-connected (cascaded/manifolded) units pro repair | More than one remote controller connected across quick-connected units; Quick-connect cable / communication wiring fault between units | No homeowner check on cascade wiring; perform a single power reset and contact a licensed technician if it returns |
Noritz water heater codes we get called for most
11 — Ignition failure – the unit failed to detect a flame at ignition (no successful light-off)
Typical causes include no/insufficient gas (empty propane tank, gas valve closed, low pressure); air or restriction in the gas line; airflow / vent blockage. A few things are safe to check yourself (Confirm the gas supply is on and another gas appliance lights normally; For propane, confirm the tank is not empty), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 11 on Noritz water heaters throughout Greater Vancouver.
12 — Flame loss – the burner lit but the flame went out (could not stay lit) during operation
Typical causes include low propane tank volume or undersized gas supply; poor / dropping gas pressure that weakens the flame; vent or air-supply disturbance. A few things are safe to check yourself (Confirm the gas supply is on and other gas appliances run without sputtering; For propane, confirm the tank level is adequate), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 12 on Noritz water heaters throughout Greater Vancouver.
14 — Thermal fuse failure / overheat-prevention device (thermal fuse around the heat exchanger) has triggered due to an overheat condition
Typical causes include heat exchanger overheating; scale buildup in the heat exchanger restricting flow; blocked or restricted water flow. A few things are safe to check yourself (Confirm the water supply to the unit is fully on and not throttled; Perform a single power reset to see if the fault clears), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 14 on Noritz water heaters throughout Greater Vancouver.
61 — Fan (combustion blower) motor abnormality – the fan is not spinning, or spinning much faster/slower than the expected RPM for the current stage
Typical causes include failed or obstructed fan motor; loose fan wiring / wire harness; temporary vent blockage (wind gusts, obstruction). A few things are safe to check yourself (Confirm the intake and exhaust vent terminations outside are clear; Perform a single power reset; an EC61 that only shows in history may have been a transient vent/voltage event), but the repair is a licensed, TSBC-certified gas technician job. HeatLand diagnoses and fixes 61 on Noritz water heaters throughout Greater Vancouver.
Is it safe to keep running a Noritz water heater with a fault code?
Most Noritz fault codes put the water heater into a safe lockout for a reason. You can safely check the basics — the gas supply on, the pilot light or igniter, the temperature dial setting, the breaker on (power-vent/electric/hybrid models), and no water leaking around the tank — and restart it once. If the code returns, stop and book a technician. If you smell gas, leave the building and call your gas utility’s emergency line or 911 first. If a carbon-monoxide alarm sounds, get everyone out and call 911. Never cap or block the temperature & pressure (T&P) relief valve, and don’t keep relighting a pilot that won’t stay lit.
Noritz water heater repair across Greater Vancouver
HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Noritz water heaters — pilot and ignition faults, gas-control (status-light) codes, sensor and thermostat errors, vent and air-intake blockages, leak shut-offs, and (on hybrid/heat-pump and tankless models) control-board and component faults — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your water heater is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.
Need it sorted fast? We offer priority emergency water heater repair. Explore Water Heater services, browse all water heater error codes by brand, or request a free estimate.
Noritz water heater service areas
We repair Noritz water heaters across Greater Vancouver and the Fraser Valley, including:
Noritz water heater error code FAQs
Can I reset my Noritz water heater myself?
Yes — power-cycling the reset button once is generally safe after you’ve checked the basics (the gas supply on, the pilot light or igniter, the temperature dial setting, the breaker on (power-vent/electric/hybrid models), and no water leaking around the tank). If the water heater faults again right away, stop and note the code — repeatedly resetting a water heater that keeps locking out can mask a real problem. Call a licensed, TSBC-certified gas technician to diagnose it.
What does the Noritz 11 code mean?
On Noritz water heaters, 11 commonly indicates ignition failure – the unit failed to detect a flame at ignition (no successful light-off). Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed, TSBC-certified gas technician. HeatLand fixes this across Greater Vancouver.
Do you repair Noritz water heaters you didn’t install?
Yes. HeatLand is brand-agnostic and services Noritz water heaters throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.
Is a Noritz water heater fault code an emergency?
No heat in cold weather is worth treating urgently. If you smell gas, leave the building and call your gas utility’s emergency line or 911 first. If a carbon-monoxide alarm sounds, get everyone out and call 911. Never cap or block the temperature & pressure (T&P) relief valve, and don’t keep relighting a pilot that won’t stay lit. For priority water heater repair across Greater Vancouver, call (604) 330-3812.
How much does Noritz water heater repair cost in Vancouver?
It depends on the fault. Many Noritz codes point to sensors, ignition or pump parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.
Noritz water heater acting up in Metro Vancouver? HeatLand’s licensed, TSBC-certified gas technicians diagnose and repair Noritz water heaters across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairMore Water Heater error-code guides
HeatLand repairs every major water heater brand across Greater Vancouver. More brand guides:
Bradford White water heater codes
55 Bradford White water heater fault codes — meanings, causes & repair.
Bosch water heater codes
32 Bosch water heater fault codes — meanings, causes & repair.
Rheem water heater codes
32 Rheem water heater fault codes — meanings, causes & repair.
John Wood water heater codes
28 John Wood water heater fault codes — meanings, causes & repair.
A O Smith water heater codes
26 A O Smith water heater fault codes — meanings, causes & repair.
Takagi water heater codes
23 Takagi water heater fault codes — meanings, causes & repair.