Seeing a fault code on your Daikin heat pump? This guide explains what the most common Daikin heat pump error codes mean, what’s safe to check yourself, and when to call HeatLand’s licensed HVAC technicians for Daikin heat pump repair across Metro Vancouver and the Fraser Valley.
The codes below apply across common Daikin models (FTX/RX (N-series split), Aurora (cold-climate ductless), FIT (side-discharge inverter heat pump), VRV/multi-split, SkyAir). Meanings follow Daikin’s documented fault codes — always confirm against your unit’s own manual, because exact wording can vary by model, control board and firmware.
How to read Daikin heat pump error codes
Two-character alphanumeric malfunction codes shown on the indoor wall unit, wired/wireless remote, or system controller. The first character is the division (A = indoor unit, C/H/J = sensors, E/F = outdoor protection, L/P = inverter/electrical, U = system/communication). Diagnosis is read by pressing the Cancel/Inspection button on the remote and stepping through codes. Same code family is shared across Daikin RA (residential split/ductless), SkyAir, FIT, and VRV product lines.
Daikin heat pump acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Daikin heat pumps across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairDaikin heat pump error codes & what they mean
These are the Daikin heat pump codes our Greater Vancouver technicians see most. Anything marked pro repair involves electrical, refrigerant, sensor or control-board work that must be done by a licensed HVAC technician — never open the indoor/outdoor unit or refrigerant lines yourself.
| Code | What it usually means | Common causes | Safe to check yourself |
|---|---|---|---|
| A1 | Indoor unit PCB (control board) abnormality / defect pro repair | Defective indoor unit control board; Power supply noise or surge to indoor PCB; Loose connector on indoor board | Turn off the unit at the wall switch/breaker for one minute, then restart once; Confirm power supply is stable |
| A3 | Drain (condensate) level control system abnormality pro repair | Blocked condensate drain line; Failed drain pump; Faulty drain float switch | Check for visible water pooling around the indoor unit and stop use if leaking |
| A5 | Freeze-up protection control (cooling) / heating peak-cut high-pressure control activated DIY-checkable | Dirty/clogged indoor air filter; Blocked indoor airflow; Low refrigerant charge | Clean or replace the indoor air filter; Make sure indoor supply/return vents and the unit face are not blocked; Restart once after cleaning |
| A6 | Indoor fan motor (DC motor) or related wiring abnormality pro repair | Failed indoor fan motor; Broken/short wiring to fan motor; Obstruction stopping the indoor fan wheel | Power off and confirm nothing is physically blocking the indoor fan; Restart once after power-cycle |
| A8 | Indoor fan (AC input/PCB) power abnormality pro repair | Abnormal AC input voltage to indoor unit; Defective indoor fan PCB | Confirm household power is stable; Power-cycle once |
| AH | Dust collector / air-cleaning (streamer) unit abnormality DIY-checkable | Dirty or contaminated dust-collection element; Air-purifier component fault | Check and clean the air-purifier/dust filter element per the owner manual; Restart once after cleaning |
| C4 | Indoor heat-exchanger (liquid-side) thermistor or related wiring abnormality pro repair | Disconnected or shorted indoor coil thermistor; Thermistor out of resistance range | Power-cycle the unit once |
| C5 | Indoor gas-side / room-temperature thermistor or related abnormality pro repair | Disconnected or shorted thermistor; Thermistor out of range | Power-cycle the unit once |
| C9 | Suction-air / remote-controller thermistor abnormality pro repair | Disconnected or shorted suction-air thermistor; Thermistor out of range | Power-cycle the unit once |
| E1 | Outdoor unit PCB (control board) abnormality / defect pro repair | Defective outdoor control board; Power surge or noise to outdoor PCB | Turn off at the breaker for one minute and restart once; Confirm the outdoor disconnect is on |
| E5 | OL (overload protector) activation — compressor motor overload or overheat pro repair | Restricted outdoor airflow; Dirty outdoor coil; Low refrigerant or overload condition | Clear snow, leaves, and debris from around and on top of the outdoor unit; Make sure there is at least the manufacturer-specified clearance around the outdoor unit; Restart once after clearing |
| E6 | Compressor startup fault / compressor lock pro repair | Seized or locked compressor; Low voltage at startup; Inverter drive fault | Confirm household voltage is stable; Power-cycle once |
| E7 | Outdoor DC fan motor fault / fan lock pro repair | Outdoor fan blade obstructed (ice/debris); Failed outdoor fan motor; Broken fan wiring | Power off and clear ice, snow, or debris jamming the outdoor fan blade; Restart once after clearing |
| E8 | Input overcurrent detection (outdoor unit AC input) pro repair | Excessive input current; Compressor or inverter overload; Supply voltage issue | Confirm the breaker and household power are stable; Power-cycle once |
| EA | Four-way (reversing) valve abnormality pro repair | Failed reversing valve or coil; Valve stuck between heat/cool; Wiring fault to valve coil | None beyond a single power-cycle |
| F3 | Abnormal discharge-pipe temperature control (compressor discharge too hot) pro repair | Low refrigerant charge; Restricted refrigerant flow / blocked expansion valve; Poor outdoor heat rejection | Clear debris/snow from the outdoor unit; Stop running the unit and call a technician — continued running can damage the compressor |
| F6 | High-pressure control activated (in cooling) pro repair | Dirty/blocked outdoor coil; Restricted outdoor airflow; Refrigerant overcharge | Clean debris off the outdoor coil and clear surrounding obstructions; Restart once after clearing |
| F8 | Compressor protection shutdown due to temperature abnormality in the compressor pro repair | Compressor overheating; Low refrigerant / poor lubrication; Sensor fault | Clear the outdoor unit of obstructions; Power-cycle once |
| H0 | Compressor system sensor (voltage/current) abnormality pro repair | Faulty compressor sensing circuit; Outdoor PCB fault | Power-cycle once |
| H6 | Compressor position-detection sensor fault (operation halted) pro repair | Inverter/compressor position-detection failure; Compressor or inverter PCB fault | Power-cycle once |
| H8 | DC voltage/current (CT) sensor fault pro repair | Faulty current sensing circuit; Abnormal input power; Outdoor PCB fault | Confirm household power is stable; Power-cycle once |
| H9 | Outdoor air temperature thermistor or related abnormality pro repair | Disconnected or shorted outdoor-air thermistor; Thermistor out of range | Power-cycle once |
| J3 | Discharge-pipe thermistor or related abnormality pro repair | Disconnected or shorted discharge-pipe thermistor; Thermistor out of range or misplaced | Power-cycle once |
| J6 | Outdoor heat-exchanger thermistor or related abnormality pro repair | Disconnected or shorted outdoor coil thermistor; Thermistor out of range | Power-cycle once |
| J8 | Liquid-pipe / sub-cooling thermistor or related abnormality pro repair | Disconnected or shorted thermistor; Thermistor out of range | Power-cycle once |
| L3 | Electrical-component (control) box temperature rise pro repair | Restricted outdoor airflow / blocked unit; Failed component-box cooling fan; Dirty heatsink | Clear obstructions and debris around the outdoor unit; Restart once after clearing |
| L4 | Inverter radiation fin (heatsink) high-temperature pro repair | Blocked outdoor unit / poor heat rejection; Dirty heatsink; High ambient temperature | Clear debris and snow from around the outdoor unit; Restart once after clearing |
| L5 | Inverter output overcurrent (DC output / instantaneous overcurrent) pro repair | Compressor fault or short; Inverter PCB fault; Compressor overload | Power-cycle once |
| P4 | Inverter radiation fin (heatsink) thermistor or related abnormality pro repair | Disconnected or shorted heatsink thermistor; Inverter PCB fault | Power-cycle once |
| U0 | Refrigerant shortage / low refrigerant (or electronic expansion valve fault) pro repair | Refrigerant leak / undercharge; Blocked or faulty electronic expansion valve; Closed service stop valve | Make sure outdoor unit is clear of obstructions; Stop running the unit and call a technician — running low on refrigerant can damage the compressor |
| U2 | Power supply voltage abnormality — low-voltage (drop) or main-circuit over-voltage detection pro repair | Low or unstable household supply voltage; Voltage spike/over-voltage; Loose power wiring | Confirm the breaker is on and household voltage is stable; Power-cycle once |
| U4 | Signal transmission failure between indoor and outdoor unit pro repair | Broken or loose indoor-outdoor signal wiring; Wrong/reversed interconnect wiring; Indoor or outdoor PCB fault | Confirm both the indoor and outdoor units have power; Power-cycle the whole system once |
| U5 | Signal transmission failure between indoor unit and remote controller pro repair | Loose/broken remote-controller wiring; Faulty remote controller; Indoor PCB fault | Check that the wired remote is seated properly; Power-cycle once |
| U7 | Signal transmission failure on the outdoor unit PCB (between control boards) pro repair | Internal outdoor wiring/connector fault; Outdoor PCB fault | Power-cycle once |
| U8 | Signal transmission failure between MAIN and SUB remote controllers pro repair | Main/sub remote setting conflict; Wiring fault between controllers | Power-cycle once |
| UA | Indoor-outdoor unit combination fault (mismatched/unspecified units or incorrect field setting) pro repair | Indoor and outdoor units are not a matched/compatible combination; Too many indoor units connected for the outdoor capacity; Incorrect address/field setting | Power-cycle the system once (this is an installation/configuration issue — a technician must verify the unit pairing) |
| UF | System not set yet — check (commissioning) operation not executed, or transmission wiring not completed pro repair | Indoor-outdoor wiring not finished or miswired; Check/test operation not performed at install; Service stop valve left closed | Power-cycle once (this is a commissioning issue — the installer/technician must complete setup) |
| UH | System malfunction — improper transmission wiring or address setting between indoor and outdoor units pro repair | Miswired indoor-outdoor transmission wiring; Incorrect unit addressing; Indoor or outdoor PCB fault | Power-cycle once (wiring/addressing must be checked by a technician) |
Daikin heat pump codes we get called for most
A1 — Indoor unit PCB (control board) abnormality / defect
Typical causes include defective indoor unit control board; power supply noise or surge to indoor pcb; loose connector on indoor board. A few things are safe to check yourself (Turn off the unit at the wall switch/breaker for one minute, then restart once; Confirm power supply is stable), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes A1 on Daikin heat pumps throughout Greater Vancouver.
C4 — Indoor heat-exchanger (liquid-side) thermistor or related wiring abnormality
Typical causes include disconnected or shorted indoor coil thermistor; thermistor out of resistance range. A few things are safe to check yourself (Power-cycle the unit once), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes C4 on Daikin heat pumps throughout Greater Vancouver.
E5 — OL (overload protector) activation — compressor motor overload or overheat
Typical causes include restricted outdoor airflow; dirty outdoor coil; low refrigerant or overload condition. A few things are safe to check yourself (Clear snow, leaves, and debris from around and on top of the outdoor unit; Make sure there is at least the manufacturer-specified clearance around the outdoor unit), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes E5 on Daikin heat pumps throughout Greater Vancouver.
A5 — Freeze-up protection control (cooling) / heating peak-cut high-pressure control activated
Typical causes include dirty/clogged indoor air filter; blocked indoor airflow; low refrigerant charge. A few things are safe to check yourself (Clean or replace the indoor air filter; Make sure indoor supply/return vents and the unit face are not blocked), but the repair is a licensed HVAC technician job. HeatLand diagnoses and fixes A5 on Daikin heat pumps throughout Greater Vancouver.
Is it safe to keep running a Daikin heat pump with a fault code?
Most Daikin fault codes put the heat pump into a safe lockout for a reason. You can safely check the basics — the power and breaker on, the indoor filter clean, the outdoor unit clear of snow, ice and debris, and the remote set to the correct mode and temperature — and restart it once. If the code returns, stop and book a technician. Mini-split and heat-pump faults are electrical and refrigerant issues — never open the indoor or outdoor unit, and never touch the wiring or refrigerant lines yourself.
Daikin heat pump repair across Greater Vancouver
HeatLand has kept Metro Vancouver homes comfortable since 1999. Our licensed, insured technicians diagnose and repair Daikin heat pumps — sensor and thermistor errors, indoor-to-outdoor communication faults, fan and compressor problems, refrigerant and pressure faults, and control-board issues — including units we didn’t install. We’re brand-agnostic, carry common parts, and give you an honest repair-or-replace assessment with upfront pricing and a free estimate. If your heat pump is beyond economical repair, we’ll show you right-sized, high-efficiency replacement options and the rebates available.
Need it sorted fast? We offer priority emergency heat pump repair. Explore Heat Pump services, browse all heat pump error codes by brand, or request a free estimate.
Daikin heat pump service areas
We repair Daikin heat pumps across Greater Vancouver and the Fraser Valley, including:
Daikin heat pump error code FAQs
Can I reset my Daikin heat pump myself?
Yes — power-cycling the unit at the breaker once is generally safe after you’ve checked the basics (the power and breaker on, the indoor filter clean, the outdoor unit clear of snow, ice and debris, and the remote set to the correct mode and temperature). If the heat pump faults again right away, stop and note the code — repeatedly resetting a heat pump that keeps locking out can mask a real problem. Call a licensed HVAC technician to diagnose it.
What does the Daikin E5 code mean?
On Daikin heat pumps, E5 commonly indicates ol (overload protector) activation — compressor motor overload or overheat. Confirm the exact meaning against your unit’s manual — codes can vary by model and series — and have the repair done by a licensed HVAC technician. HeatLand fixes this across Greater Vancouver.
Do you repair Daikin heat pumps you didn’t install?
Yes. HeatLand is brand-agnostic and services Daikin heat pumps throughout Metro Vancouver and the Fraser Valley, whether or not we installed the unit. We carry common parts and give you an honest repair-or-replace assessment.
Is a Daikin heat pump fault code an emergency?
No heat in cold weather or no cooling in a heat wave is worth treating urgently. For priority heat pump repair across Greater Vancouver, call (604) 330-3812.
How much does Daikin heat pump repair cost in Vancouver?
It depends on the fault. Many Daikin codes point to sensors, thermistors, capacitors or control parts — usually far cheaper than replacement. We give upfront pricing and a free estimate before any work.
Daikin heat pump acting up in Metro Vancouver? HeatLand’s licensed HVAC technicians diagnose and repair Daikin heat pumps across Greater Vancouver — including units we didn’t install.
Call (604) 330-3812Get a free repair estimateNo heat? Emergency repairMore Heat Pump error-code guides
HeatLand repairs every major heat pump brand across Greater Vancouver. More brand guides:
Fujitsu heat pump codes
44 Fujitsu heat pump fault codes — meanings, causes & repair.
Lennox heat pump codes
44 Lennox heat pump fault codes — meanings, causes & repair.
LG heat pump codes
40 LG heat pump fault codes — meanings, causes & repair.
Bosch heat pump codes
39 Bosch heat pump fault codes — meanings, causes & repair.
Mitsubishi heat pump codes
37 Mitsubishi heat pump fault codes — meanings, causes & repair.
Samsung heat pump codes
35 Samsung heat pump fault codes — meanings, causes & repair.